Impact of point A asymmetry on local control and survival for low dose-rate (LDR) brachytherapy in cervical cancer

نویسندگان

  • Krisha J Opfermann
  • Amy Wahlquist
  • John Watkins
  • Matthew Kohler
  • Joseph Jenrette
چکیده

PURPOSE To evaluate whether Point A asymmetry in low dose-rate (LDR) brachytherapy is associated with local control (LC), disease-free survival (DFS) and/or overall survival (OS). MATERIAL AND METHODS A retrospective analysis of disease control and survival outcomes was conducted for patients who underwent LDR brachytherapy for advanced cervical cancer. Institutional protocol entailed concurrent chemotherapy and whole pelvis radiotherapy (WPRT) over 5 weeks, followed by placement of Fletcher-Suit tandem and colpostat applicators at weeks 6 and 8. Objective Point A doses, 80-85 Gy, were accomplished by placement of Cesium-137 (Cs-137) sources. Cox proportional hazards regression models were used to assess associations between disease control and survival endpoints with variables of interest. RESULTS The records of 50 patients with FIGO stage IB1-IVA cervical cancer undergoing LDR brachytherapy at our institution were identified. Thirty of these patients had asymmetry > 2.5%, and 11 patients had asymmetry > 5%. At a median survivor follow-up of 20.25 months, 15 patients had experienced disease failure (including 5 cervical/vaginal apex only failures and 2 failures encompassing the local site). Right/left dose asymmetry at Point A was associated with statistically significantly inferior LC (p = 0.035) and inferior DFS (p = 0.011) for patients with mean Point A dose of > 80 Gy. Insufficient evidence existed to conclude an association with OS. CONCLUSIONS LDR brachytherapy may be associated with clinically significant dose asymmetry. The present study demonstrates that patients with Point A asymmetry have a higher risk of failure for DFS and LC.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

درمان داخل حفره‌ای در مبتلایان سرطان سرویکس: پرتودهی با دوز متوسط در یک مطالعه آینده‌نگر

Background: Treatment of cervical carcinoma is routinely performed with Low Dose Rate (LDR) brachytherapy, but Brachytherapy in our department is done with Medium Dose Rate (MDR) due to the technical characteristics of the machine available here. Thus we decided to evaluate the results of this treatment in our department in a prospective study. Methods: Between March 2006 and July 2008, 140 pa...

متن کامل

Brachytherapy for cervix cancer: low-dose rate or high-dose rate brachytherapy – a meta-analysis of clinical trials

BACKGROUND The literature supporting high-dose rate brachytherapy (HDR) in the treatment of cervical carcinoma derives primarily from retrospective series. However, controversy still persists regarding the efficacy and safety of HDR brachytherapy compared to low-dose rate (LDR) brachytherapy, in particular, due to inadequate tumor coverage for stage III patients. Whether LDR or HDR brachytherap...

متن کامل

We should not settle for low-level evidence but should always use the best available evidence

To the editor: We would like to thank Dr. Mirza [1] for his editorial in response to our paper [2] on " Ultrasound guided conformal brachytherapy of cervix cancer: survival, patterns of failure, and late complications. " He has raised several questions about our study, which we would like to address. Firstly, we would like to clarify that this study is based on data from our prospective unit da...

متن کامل

”Maximum dose” points in cervical and endometrial cancer medium dose rate brachytherapy

Background: Best dose distribution in target volume and control of Organ at Risk (OAR) dose are the two main goals in brachytherapy. Materials and Methods: In this study in vivo dosimetry in 4 rectal points was performed by Transillumination Dosimeter (TLD) s and the measured doses were compared in different patients. One point was reported to have the maximum dose in each patient and the very ...

متن کامل

Simulation of the shielding effects of an applicator on the AAPM TG-43 parameters of CS-137 Selectron LDR brachytherapy sources

Background: The dose rate distribution delivered by a low dose rate 137Cs pellet source, a spherical source used within the source trains of the Selectron gynecological brachytherapy system, was investigated using the MCNP4C Monte Carlo code. Materials and Methods: The calculations were performed in both water and Plexiglas and the absolute dose rate distribution for a single pellet s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2012