The diagnosis of herniated intervertebral disks with MR imaging: a comparison of gradient-refocused-echo and spin-echo pulse sequences.
نویسندگان
چکیده
Axial MR images of 65 lumbar disks with herniated nucleus pulposus imaged by gradient-refocused-echo (GRE) and spin-echo (SE) MR pulse sequences of 200-400/15 with a flip angle of 15-30 degrees was selected as optimal because of its high signal-to-noise ratio and good contrast between CSF, nucleus pulposus, and bone. The GRE technique was confirmed to be more sensitive in detecting prolapsed disks than the SE technique, but was less sensitive in demonstrating extruded disks. The combination of axial GRE and SE resulted in high detectability of herniated nucleus pulposus on axial MR images. Our results suggest that the GRE technique is an important adjunct to SE imaging in studying herniated nucleus pulposus.
منابع مشابه
Cervical spine: postmortem assessment of accident injuries--comparison of radiographic, MR imaging, anatomic, and pathologic findings.
PURPOSE To assess the ability of postmortem radiography and magnetic resonance (MR) imaging to depict occult cervical spine injuries as compared with anatomic and pathologic findings. MATERIALS AND METHODS The cervical spines of 10 adult accident victims underwent radiography and MR imaging, with T1-weighted, fast spin-echo T2-weighted, and four gradient-echo pulse sequences. The frozen speci...
متن کاملI-42: MRI Evaluation of Congenital Uterine Anomalies
Mullerian duct anomalies are an uncommon but often treatable cause of infertility. Patients with müllerian duct anomalies are known to have a higher incidence of infertility, repeated first-trimester spontaneous abortions, fetal intrauterine growth retardation, fetal malposition, preterm labor, and retained placenta. The role of imaging is to help detect, diagnose, and distinguish surgically co...
متن کاملAssessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences
Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of non-homogeneity in RF receive and transmit. This can be the most effective source of error in quantitative studies in MRI imaging. Part of this non-homogeneity demonstrates the characteristics of RF coil and part of it is due to the interaction of RF field with the material being imaged...
متن کاملComparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm
Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...
متن کاملComparison of MR pulse sequences in the detection of multiple sclerosis lesions.
PURPOSE To compare the sensitivity of conventional spin-echo, fast spin-echo, fast fluid-attenuated inversion recovery (FLAIR), and turbo gradient spin-echo MR sequences in the detection of multiple sclerosis lesions. METHODS Conventional spin-echo, fast spin-echo, fast FLAIR, and turbo gradient spin-echo sequences were performed on a 1.0-T MR imager in seven patients with clinically definite...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 11 1 شماره
صفحات -