OBJECTIVE To assess the Omron 705-CP monitor for measuring blood pressure in adolescents and young adults. METHODS According to the protocols of the British Hypertension Society and the Association for the Advancement of Medical Instrumentation, we performed validation of the device in 60 adolescents. The Omron monitor was connected in Y to a mercury column. Four consecutive and simultaneous measurements were taken with the mercury column sphygmomanometer and the test device, were independently analyzed, and the mean differences between the blood pressure measurements and the standard deviations of those differences were calculated. The results were analyzed according to the grading system of the protocol used. RESULTS Two hundred and forty measurements were evaluated. The mean age of the patients was 16.3 years. When the measurement performed with the mercury column sphygmomanometer was compared with that taken with the device, a difference < or =15 mmHg was observed in 97.9% of the systolic and 98.8% of the diastolic blood pressure measurements; a difference < or =10 mmHg was observed in 86.3% of the systolic and 90.4% of the diastolic blood pressure measurements, which was classified as grade A; a difference < or =5 mmHg was observed in 59.1% of the systolic and 67% of the diastolic blood pressure measurements, and was classified as grade A/B. The mean difference and the standard deviation of that difference for the systolic blood pressure was 2.91+/-6.42 mmHg, and, for the diastolic blood pressure, it was 1.16+/-5.79 mmHg. CONCLUSION The Omron 705-CP monitor proved to be useful for measuring blood pressure in adolescents according to the protocol used.
منابع مشابه
Accuracy of the Omron HEM-705 CP for blood pressure measurement in large epidemiologic studies.
BACKGROUND Accurate measurement of blood pressure is of utmost importance in hypertension research. In the context of epidemiologic and clinical studies, oscillometric devices offer important advantages to overcome some of the limitations of the auscultatory method. Even though their accuracy has been evaluated in multiple studies in the clinical setting, there is little evidence of their perfo...
متن کاملEvaluation of the accuracy of the Omron HEM-907 blood pressure device.
A study was undertaken to assess the accuracy of the Omron HEM-907 blood pressure measuring device for use in community studies. A modified version of the British Hypertension Society (BHS) and American Association for the Advancement Medical Instrumentation (AAMI) protocol for measuring the accuracy of a blood pressure measuring device was used. A total of 104 subjects were recruited from two ...
متن کاملInaccuracy of wrist-cuff oscillometric blood pressure devices: an arm position artefact?
BACKGROUND Despite the increasing popularity of wrist-cuff blood pressure (BP) devices, their accuracy has not been established and international guidelines do not support their use. Because arm position influences BP measurement, it is possible that conflicting reports on wrist-cuff device accuracy reflects diverse arm positions. METHOD This study compared BP measured by two oscillometric de...
متن کاملEffectiveness of Tobacco Control Measures in Reducing Tobacco Use among Adolescents and Young Adults in Anuradhapura, Sri Lanka
Background: Sri Lanka became a signatory to the WHO Framework Convention on Tobacco Control in September 2003 and ratified in November 2003. Aiming to reduce tobacco burden in Sri Lanka, National Authority on Tobacco and Alcohol Act [NATA] No. 27 was authorized in 2006. The objective of this study was to assess the behavioral changes related to tobacco use among adolescents and young adults fol...
متن کاملگزارش یک مورد: ارسال فشار خون و نبض بیمار به پزشک با استفاده از سیستم Global system for Mobile Communications
Background: Hypertension is a common chronic disease with increasing prevalence worldwide. Regular close monitoring of blood pressure is key point of hypertension management. Home monitoring of blood pressure has its own problems such as lack of early access to a physician in case of emergency. In this study we have designed a device that could send the patient’s self-measured blood pre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Arquivos brasileiros de cardiologia
دوره 84 5 شماره
صفحات -
تاریخ انتشار 2005