PEAR: PEriodic And fixed Rank separation for fast fMRI
نویسندگان
چکیده
PURPOSE In functional MRI (fMRI), faster acquisition via undersampling of data can improve the spatial-temporal resolution trade-off and increase statistical robustness through increased degrees-of-freedom. High-quality reconstruction of fMRI data from undersampled measurements requires proper modeling of the data. We present an fMRI reconstruction approach based on modeling the fMRI signal as a sum of periodic and fixed rank components, for improved reconstruction from undersampled measurements. METHODS The proposed approach decomposes the fMRI signal into a component which has a fixed rank and a component consisting of a sum of periodic signals which is sparse in the temporal Fourier domain. Data reconstruction is performed by solving a constrained problem that enforces a fixed, moderate rank on one of the components, and a limited number of temporal frequencies on the other. Our approach is coined PEAR - PEriodic And fixed Rank separation for fast fMRI. RESULTS Experimental results include purely synthetic simulation, a simulation with real timecourses and retrospective undersampling of a real fMRI dataset. Evaluation was performed both quantitatively and visually versus ground truth, comparing PEAR to two additional recent methods for fMRI reconstruction from undersampled measurements. Results demonstrate PEAR's improvement in estimating the timecourses and activation maps versus the methods compared against at acceleration ratios of R = 8,10.66 (for simulated data) and R = 6.66,10 (for real data). CONCLUSIONS This paper presents PEAR, an undersampled fMRI reconstruction approach based on decomposing the fMRI signal to periodic and fixed rank components. PEAR results in reconstruction with higher fidelity than when using a fixed-rank based model or a conventional Low-rank + Sparse algorithm. We have shown that splitting the functional information between the components leads to better modeling of fMRI, over state-of-the-art methods.
منابع مشابه
Independent Component Analysis of Functional Magnetic Resonance Imaging (fMRI) Data: A simple Approach
Independent Component Analysis (ICA) separates spatial and temporal components of fMRI data which may consist of activation patterns, cardiac and respiratory tasks and other artifacts. In this study sources of (fMRI) data are separated using ICA based on simple fixed point iteration method and steepest ascent method. Both are the simplest methods used in optimization. However in this study comp...
متن کاملNew fixed and periodic point results on cone metric spaces
In this paper, several fixed point theorems for T-contraction of two maps on cone metric spaces under normality condition are proved. Obtained results extend and generalize well-known comparable results in the literature.
متن کاملImproving the Performance of ICA Algorithm for fMRI Simulated Data Analysis Using Temporal and Spatial Filters in the Preprocessing Phase
Introduction: The accuracy of analyzing Functional MRI (fMRI) data is usually decreases in the presence of noise and artifact sources. A common solution in for analyzing fMRI data having high noise is to use suitable preprocessing methods with the aim of data denoising. Some effects of preprocessing methods on the parametric methods such as general linear model (GLM) have previously been evalua...
متن کاملExistence and uniqueness of solutions for neutral periodic integro-differential equations with infinite delay
...
متن کاملSingular operators in multiwavelet bases
We review some recent results on multiwavelet methods for solving integral and partial differential equations and present an efficient representation of operators using discontinuous multiwavelet bases, including the case for singular integral operators. Numerical calculus using these representations produces fast O(N) methods for multiscale solution of integral equations when combined with low...
متن کامل