Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens
نویسندگان
چکیده
Purpose The purpose of this study was to compare the visual outcomes and subjective visual quality between bilateral implantation of a diffractive trifocal intraocular lens, Alcon Acrysof IQ® PanOptix® TNFT00 (group A), and blended implantation of an extended depth of focus lens, J&J Tecnis Symfony® ZXR00 with a diffractive bifocal intraocular lens, J&J Vision Tecnis® ZMB00 (group B). Methods This prospective, nonrandomized, consecutive, comparative study included the assessment of 40 eyes in 20 patients implanted with multifocal intraocular lens. Exclusion criteria were existence of any corneal, retina, or optic nerve disease, previous eye surgery, illiteracy, previous refractive surgery, high axial myopia, expected postoperative corneal astigmatism of >1.00 cylindrical diopter (D), and intraoperative or postoperative complications. Binocular visual acuity was tested in all cases. Ophthalmological evaluation included the measurement of uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), and uncorrected intermediate visual acuity (UIVA), with the analysis of contrast sensitivity (CS), and visual defocus curve. Results Postoperative UDVA was 0.01 and -0.096 logMAR (p<0.01) in groups A and B, respectively; postoperative CDVA was -0.07 and -0.16 logMAR (p<0.01) in groups A and B, respectively; UIVA was 0.14 and 0.20 logMAR (p<0.01) in groups A and B, respectively; UNVA was -0.03 and 0.11 logMAR (p<0.01) in groups A and B, respectively. Under photopic conditions group B had better CS at low frequencies with and without glare. Conclusion Both groups promoted good quality of vision for long, intermediate, and short distances. Group B exhibited a better performance for very short distances and for intermediate and long distances ≥-1.50 D of vergence. Group A exhibited a better performance for UIVA at 60 cm and for UNVA at 40 cm.
منابع مشابه
Comparison between bilateral implantation of a trifocal intraocular lens and blended implantation of two bifocal intraocular lenses
PURPOSE To compare visual outcomes and performance between bilateral implantation of a diffractive trifocal intraocular lens (IOL) Acrysof®PanOptix® TFNT00 and blended implantation of two different near add power bifocal IOLs: Acrysof® Restor® SV25T0 in dominant eye and Acrysof® Restor® SN6AD1 in the nondominant eye. METHODS This prospective, nonrandomized, consecutive and comparative study a...
متن کاملComparison of visual outcomes and subjective visual quality after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of apodized diffractive bifocal intraocular lenses
PURPOSE To compare the visual acuity (VA) and quality of vision between bilateral implantation of a trifocal intraocular lens (IOL) and blended bifocal IOLs with an intermediate add in the dominant eye and a near add in the nondominant eye. PATIENTS AND METHODS Patients with either trifocal or blended bifocal IOLs implanted were recruited after surgery. Subjects returned for a single diagnost...
متن کاملComparison of visual outcomes after implantation of diffractive trifocal toric intraocular lens and a diffractive apodized bifocal toric intraocular lens.
PURPOSE The aim of this study was to compare a new diffractive trifocal toric lens with an apodized diffractive bifocal toric lens in terms of refractive and visual acuity (VA) outcomes, including low-contrast VA (LCVA), as well as the patient's visual function 3 months after implantation. PATIENTS AND METHODS This is a randomized prospective study involving bilateral implantation of a trifoc...
متن کاملClinical outcomes of a new diffractive trifocal intraocular lens with Enhanced Depth of Focus (EDOF)
BACKGROUND To evaluate the clinical outcomes after the implantation of a new trifocal diffractive intraocular lens (IOL) combined with Enhanced depth of focus (EDOF) technology. METHODS The study enrolled 80 eyes of 40 patients who underwent cataract surgery with bilateral implantation of a diffractive trifocal IOL (Reviol Tri-ED) designed with a combination of enhanced depth of focus. Mean a...
متن کاملClinical Outcomes after Binocular Implantation of a New Trifocal Diffractive Intraocular Lens
Purpose. To evaluate visual, refractive, and contrast sensitivity outcomes, as well as the incidence of pseudophakic photic phenomena and patient satisfaction after bilateral diffractive trifocal intraocular lens (IOL) implantation. Methods. This prospective nonrandomized study included consecutive patients undergoing cataract surgery with bilateral implantation of a diffractive trifocal IOL (A...
متن کامل