Exact fan-beam image reconstruction algorithm for truncated projection data acquired from an asymmetric half-size detector.

نویسندگان

  • Shuai Leng
  • Tingliang Zhuang
  • Brian E Nett
  • Guang-Hong Chen
چکیده

In this paper, we present a new algorithm designed for a specific data truncation problem in fan-beam CT. We consider a scanning configuration in which the fan-beam projection data are acquired from an asymmetrically positioned half-sized detector. Namely, the asymmetric detector only covers one half of the scanning field of view. Thus, the acquired fan-beam projection data are truncated at every view angle. If an explicit data rebinning process is not invoked, this data acquisition configuration will reek havoc on many known fan-beam image reconstruction schemes including the standard filtered backprojection (FBP) algorithm and the super-short-scan FBP reconstruction algorithms. However, we demonstrate that a recently developed fan-beam image reconstruction algorithm which reconstructs an image via filtering a backprojection image of differentiated projection data (FBPD) survives the above fan-beam data truncation problem. Namely, we may exactly reconstruct the whole image object using the truncated data acquired in a full scan mode (2pi angular range). We may also exactly reconstruct a small region of interest (ROI) using the truncated projection data acquired in a short-scan mode (less than 2pi angular range). The most important characteristic of the proposed reconstruction scheme is that an explicit data rebinning process is not introduced. Numerical simulations were conducted to validate the new reconstruction algorithm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast System Matrix Calculation in CT Iterative Reconstruction

Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...

متن کامل

Cone-Beam Iterative Reconstruction of a Segment of a Long Object

This study was performed to investigate the iterative reconstruction of a segment of a long object using cone-beam projections acquired with a practical-sized detector. This reconstruction problem is commonly called the cone-beam long object problem. The cone-beam focal-point trajectories studied were either helical or helical with planar arcs. We assume that the long object is confined in a ta...

متن کامل

Image reconstruction in peripheral and central regions-of-interest and data redundancy.

Algorithms have been developed for image reconstruction within a region-of-interest (ROI) from fan-beam data less than that required for reconstructing the entire image. However, these algorithms do not admit truncated data. In this work, we investigate exact ROI-image reconstruction from fan-beam data containing truncations by use of the so-called fan-beam backprojection-filtration (BPF) algor...

متن کامل

3D Image Reconstruction from Truncated Helical Cone Beam Projection Data - A Linear Prediction Approach

With the introduction of 2D flat-panel X-ray detectors, 3D image reconstruction using helical cone-beam tomography is fast replacing the conventional 2D reconstruction techniques. In 3D image reconstruction, the source orbit or scanning geometry should satisfy the data sufficiency or completeness condition for exact reconstruction. The helical scan geometry satisfies this condition and hence ca...

متن کامل

Cone-Beam Iterative Recomtruction of a Segment of a Long Object

This study was performed to investigate the iterative reconstruction of a segment of a long object using cone-beam projections acquired with a practical-size detector. This reconstruction problem is commonly called the cone-beam long object problem. The cone-beam focal-point trajectories studied were either helical or helical with planar arcs. We assume that the long object is confined in a tal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 50 8  شماره 

صفحات  -

تاریخ انتشار 2005