Percutaneous endovascular aortic aneurysm repair: a prospective evaluation of safety, efficiency, and risk factors.
نویسندگان
چکیده
PURPOSE To evaluate the efficiency of totally percutaneous endovascular aortic aneurysm repair in a large cohort of patients and to define risk factors for failure with a 10-F vascular closure system. METHODS A prospective study examined the feasibility and safety of percutaneous femoral artery closure with a single Prostar XL 10-F vascular closure device applied in conjunction with the preclose technique. Between January 2004 and December 2005, 535 consecutive patients were treated for aortic aneurysmal disease. Thirty-five patients were excluded, leaving 500 patients (417 men; mean age 72+/-6.6 years) treated for aortic aneurysms using the Talent or Zenith stent-graft delivered through sheaths measuring 14-F (191, 21.2%), 16-F (33, 3.7%), 18-F (179, 19.8%), 20-F (2, 0.2%), 22-F (228, 25.2%), and 24-F (271, 29.9%). Primary clinical success was defined as the freedom from additional early or late procedures to treat any complication at the access site. Data were analyzed to reveal any correlation of access site complications or early/late repairs to operator experience or risk factors (obesity, extensive femoral artery calcification, and previous interventions/scars in the groin). RESULTS Primary success was achieved in 96.1% of all percutaneous approaches. Twenty-three patients developed early (n = 16) or late (n = 7) complications at the access vessel; in 12 cases, hemostasis was achieved using pledgets with the Prostar sutures. No wound complications were recorded. The need for early conversion to an open access correlated with CFA calcification (OR 74.5, 95% CI 17.8 to 310.7; p<0.001) and operator experience (OR 43.2, 95% CI 9.8 to 189.0; p<0.001). The risk of late access site repairs was significantly higher in the presence of a groin scar (OR 48.8, 95% CI 9.2 to 259.0; p<0.001). Correlation of sheath size with early conversion to open access was weaker compared to all the other factors (OR 1.2, CI 95% 1.0 to 1.4; p<0.05). Obesity was not a risk factor for any complication. CONCLUSION Percutaneous EVAR using the Prostar XL is safe, with minimal early and late complications. Operator experience is one of the most significant predictors of success. Anterior wall calcification and severe fibrosis of the access vessel are also predictors of primary failure, whereas obesity and sheath size are not.
منابع مشابه
An Aortoenteric Fistula Arising after Endovascular Management of a Mycotic Abdominal Aortic Aneurysm Complicated with a Psoas Abscess
Mycotic aortic aneurysms account for 1–3% of all aortic aneurysms. The management of this disease is controversial. Since open surgical repair is associated with high morbidity and mortality rates, endovascular aneurysm repair is an alternative treatment method with promising early and midterm outcomes, although its long-term durability is unknown.Secondary aortoenteric fistulas may occur iatro...
متن کاملRenal insufficiency after infrarenal abdominal aortic aneurysm reconstruction: An analysis of this risk factor in 45 patients
Abstract Background: Renal insufficiency is a potential complication after infrarenal abdominal aortic aneurysm repair and is a significant risk factor for postoperative mortality and morbidity. The aim of this study was to analyze the effect of this risk factor, before and during operation. Methods: In this prospective study, between 2003 and 2006, 45 patients underwent repair of an infrarena...
متن کاملFrequency of Complications Following Endovascular Repair of Abdominal Aortic Aneurysm in Tehran Sina Hospital, 2011-2019
Background and purpose: Abdominal aortic aneurysms (AAA) is a localized enlargement of infrarenal abdominal aorta. Endovascular aneurysm repair (EVAR) is a surgical method introduced for AAA repair. This study, for the first time in Iran, investigated the complications and mortality rate associated with EVAR. Materials and methods: In this cross-sectional study, medical records were reviewed...
متن کاملPercutaneous repair of aortic aneurysms: a prospective study of suture-mediated closure devices.
PURPOSE To evaluate prospectively the safety and efficacy of totally percutaneous placement of abdominal and thoracic aortic endografts using the Prostar XL suture-mediated closure system. METHODS From January 2002 to January 2005, we attempted to insert percutaneously all bifurcated abdominal aortic and thoracic endografts. Consecutive patients (25 men, four women), with mean age 74.9 years ...
متن کاملAORTIC TRANSECTION AND ITS SURGICAL REPAIR: A CASE REPORT FROM IRAN
Aortic transection is a rare but life-threatening complication of blunt chest trauma. Treatment options include open repair, medical management and most recently, endovascular repair. We report a 33 years old male with a traumatic aortic transection following a car accident. Aortic injury and its pseudo-aneurysm were confirmed by Chest CT scan and TEE in the descending thoracic aorta just belo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
دوره 16 6 شماره
صفحات -
تاریخ انتشار 2009