On the Influence of Cancellous Bone Structure Upon the Electric Field Distribution of Electrostimulative Implants
نویسندگان
چکیده
At the University of Rostock, a new electrostimulative total hip revision system is being developed [1]. This system utilizes the accelerating effect of electromagnetic fields on bone regeneration as it has been characterized by Bassett et al. in 1974 [2]. Though this effect is already utilized in several medical applications to enhance bone regeneration after fractures or bone diseases, there is only a partial understanding of the underlying biological effects. In previous works the macroscopic field distribution around the implant has been investigated in a layered bone model. All the biological tissues (cancellous bone, cortical bone, blood etc.) have been defined as homogenous material with homogenous electrical properties. Nevertheless, especially cancellous bone is not a homogenous tissue. It is a complex material consisting of inorganic material (hydroxylapatite), organic material (collagen) and fluids forming a trabecular structure. Thus the electric field varies accordingly within this structure. This is investigated in the present work. The basic idea is to correlate the density of the different materials with the electrical properties. Therefore, the density data of a cylindrical bone sample (radius: 6 mm, height: 13 mm) has been determined with a Micro-CT (voxel size of 26 μm). The processed gray scale values of this Micro-CT-scan are imported into COMSOL Multiphysics® and used as a position-dependent parameter within a cylindrical domain to define the conductivity mathematically. The electrical properties of collagen and hydroxylapatite are taken from literature and are each assigned to a certain gray scale value. For the correlation of all the other gray scale values different mathematical approaches are tested. For example, figure 1 shows the conductivity distribution of the exponential approach. In addition, a linear and a sigmoidal approach have been simulated. To resolve the 83 million voxels of the Micro-CT-scan different mesh types have been tested with a convergence analysis. The electric field within the sample is impressed by defining the upper and lower boundary with 0.455 V and -0.455 V, respectively. Using these voltages, a homogenous material would be stimulated with 70 V/m. Since this is the upper limit for the stimulation system, we are interested in the location of overstimulation within the inhomogeneous tissue. Figure 2 shows the electric field of the example of figure 1 and it can be seen, that there is overstimulation especially in the areas of the non-conducting hydroxylapatite.
منابع مشابه
Evaluating the impact of length and thread pitch on the stress distribution in dental implants and surrounding bone using finite element method
longevity of osseointegrated implants are intensely influenced by biomechanical factors. Control of these factors prevents mechanical complications, which include fracture of screws, components, or materials veneering the framework. In this study, the impact of length and threads pitch of dental implants on the stress distribution and maximum Von Mises stress in implant-abutment complex and ja...
متن کاملInvestigation of the Electric Field Distribution within an Electro- stimulated Microstructure of Cancellous Bone
Electrostimulative fields are used to accelerate bone regeneration after fractures and to treat bone diseases. Most of these systems have upper and lower thresholds for electromagnetic fields, which have proven to have a positive effect towards bone growth. The biomechanical background, however, is still subject of ongoing research. Using numerical simulation, this paper investigates the field ...
متن کاملEffect of Abutment Height Difference on Stress Distribution in Mandibular Overdentures: A Three-Dimensional Finite Element Analysis
Background and Aim: Implant-supported overdentures are a treatment option for edentulous patients. One of the important factors in determining the prognosis of overdenture treatment is to control the distribution of stress in the implant-bone and attachment complex. This study assessed the effect of implant abutment height difference on stress distribution in mandibular overdentures. Materials...
متن کاملEvaluation of Strain Distribution in Bone around Implant in Treatment Design of Overdentures Using Computer and Modeling of Finite Elements
Introduction: Introduction: Few studies have investigated the distribution of stress around implants. In this study the distribution of stress in bones around implants was investigated in five overdenture (OD) treatment designs including OD-1, OD-2, OD-3, OD-4 and OD-5. Materials and methods: The Catia modeling software was used in order to simulate the tooth/implant model and bone. First, the ...
متن کاملDetermination of Electric Field at Inception Based upon Current-Voltage Characteristics of AC Corona in Rod-Plane Gaps
This paper deals with the measurement of AC corona inception voltage, Vincp, at the tip of a rod electrode using a hemispherically-capped rod-plane electrode configuration for various rod radii with a short air gap. Effects of atmospheric pressure and temperature variation on Vincp are investigated experimentally. An empirical equation for the field form factors of the hemispherically cappe...
متن کامل