Within-Home versus Between-Home Variability of House Dust Endotoxin in a Birth Cohort

نویسندگان

  • Joseph H. Abraham
  • Diane R. Gold
  • Douglas W. Dockery
  • Louise Ryan
  • Ju-Hyeong Park
  • Donald K. Milton
چکیده

Endotoxin exposure has been proposed as an environmental determinant of allergen responses in children. To better understand the implications of using a single measurement of house dust endotoxin to characterize exposure in the first year of life, we evaluated room-specific within-home and between-home variability in dust endotoxin obtained from 470 households in Boston, Massachusetts. Homes were sampled up to two times over 5-11 months. We analyzed 1,287 dust samples from the kitchen, family room, and baby's bedroom for endotoxin. We fit a mixed-effects model to estimate mean levels and the variation of endotoxin between homes, between rooms, and between sampling times. Endotoxin ranged from 2 to 1,945 units per milligram of dust. Levels were highest during summer and lowest in the winter. Mean endotoxin levels varied significantly from room to room. Cross-sectionally, endotoxin was moderately correlated between family room and bedroom floor (r = 0.30), between family room and kitchen (r = 0.32), and between kitchen and bedroom (r = 0.42). Adjusting for season, the correlation of endotoxin levels within homes over time was 0.65 for both the bedroom and kitchen and 0.54 for the family room. The temporal within-home variance of endotoxin was lowest for bedroom floor samples and highest for kitchen samples. Between-home variance was lowest in the family room and highest for kitchen samples. Adjusting for season, within-home variation was less than between-home variation for all three rooms. These results suggest that room-to-room and home-to-home differences in endotoxin influence the total variability more than factors affecting endotoxin levels within a room over time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Home Endotoxin Exposure and Wheeze in Infants: Correction for Bias Due to Exposure Measurement Error

Exposure to elevated levels of endotoxin in family-room dust was previously observed to be significantly associated with increased wheeze in the first year of life among a cohort of 404 children in the Boston, Massachusetts, metropolitan area. However, it is likely that family-room dust endotoxin was a surrogate for airborne endotoxin exposure. Therefore, a related substudy characterized the re...

متن کامل

Predictors of airborne endotoxin in the home.

We identified home characteristics associated with the level of airborne endotoxin in 111 Boston-area homes enrolled in a cohort study of home exposures and childhood asthma, and we developed a predictive model to estimate airborne endotoxin. We measured endotoxin in family-room air and in dust from the baby's bed, family room, bedroom, and kitchen floor. Level of airborne endotoxin was weakly ...

متن کامل

Longitudinal study of dust and airborne endotoxin in the home.

To characterize the seasonal variability of endotoxin levels, we measured endotoxin in dust from the bed, bedroom floor, and kitchen floor in 20 homes, and in air from the bedroom in 15 of the homes. All homes were located in the greater Boston, Massachusetts, area and were sampled each month from April 1995 to June 1996. Outdoor air was collected at two locations. We found greater within-home ...

متن کامل

Microbial content of household dust associated with exhaled NO in asthmatic children.

Exhaled nitric oxide (eNO) is increasingly used as a non-invasive measure of airway inflammation. Despite this, little information exists regarding the potential effects of indoor microbial components on eNO. We determined the influence of microbial contaminants in house dust and other indoor environmental characteristics on eNO levels in seven-year-olds with and without a physician-diagnosis o...

متن کامل

Characterization of lipopolysaccharides present in settled house dust.

The 3-hydroxy fatty acids (3-OHFAs) in lipopolysaccharides (LPS) play an important role in determining endotoxin activity, and childhood exposure to endotoxin has recently been associated with reduced risk of atopic diseases. To characterize the 3-OHFAs in house dust (HD), we used gas chromatography-mass spectrometry to assay 190 HD samples. Dust from beds, bedroom floors, family rooms, and kit...