Class IC antiarrhythmic drug induced atrial flutter: electrocardiographic and electrophysiological findings and their importance for long term outcome after right atrial isthmus ablation.

نویسندگان

  • A Nabar
  • L M Rodriguez
  • C Timmermans
  • R van Mechelen
  • H J Wellens
چکیده

OBJECTIVE To describe the electrocardiographic and electrophysiological findings of new atrial flutter developing in patients taking class IC antiarrhythmic drugs for recurrent atrial fibrillation, and to report the long term results of right atrial isthmus ablation in relation to the ECG pattern of spontaneous atrial flutter. DESIGN Retrospective analysis. SETTING Tertiary care academic hospital. PATIENTS 24 consecutive patients with atrial fibrillation (age 54 (12) years; 5 female, 19 male) developing atrial flutter while taking propafenone (n = 12) or flecainide (n = 12). RESULTS The ECG was classified as typical (n = 13; 54%) or atypical atrial flutter (n = 8) or coarse atrial fibrillation (n = 3). Counterclockwise atrial flutter was the predominant arrhythmia. Acute success after isthmus ablation was similar in patients with typical (12/13) and atypical (8/8) atrial flutter. After long term follow up (13 (6) months, range 6-26 months), continuation of antiarrhythmic drug treatment appeared to result in better control of recurrences of atrial fibrillation in patients with typical atrial flutter (11/13) than in those with atypical atrial flutter (4/8), but the difference was not significant. Ablation for coarse atrial fibrillation was unsuccessful. CONCLUSIONS New atrial flutter developing in patients taking class IC antiarrhythmic drugs for recurrent atrial fibrillation has either typical or atypical flutter wave morphology on ECG. The endocardial activation pattern and the acute results of ablation suggest that the flutter circuit was located in the right atrium and that the isthmus was involved in the re-entry mechanism. There appeared to be better long term control of recurrent atrial fibrillation in patients with typical (85%) as compared with atypical atrial flutter (50%). Patients developing coarse atrial fibrillation may not be candidates for this strategy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of right atrial isthmus ablation on the occurrence of atrial fibrillation: observations in four patient groups having type I atrial flutter with or without associated atrial fibrillation.

BACKGROUND The goal of this study was to test the hypothesis that the occurrence of atrial fibrillation (AF), in at least some patients with coexisting type I atrial flutter (AFL), is based on macro-reentry around the tricuspid valve orifice, including the right atrial (RA) isthmus, by evaluation of AF recurrences after successful ablation of AFL. METHODS AND RESULTS Eighty-two consecutive pa...

متن کامل

Isthmus Dependent Atrial Flutter Cycle Length Correlates with Right Atrial Cross-Sectional Area

BACKGROUND Right atrial flutter cycle length can prolong in the presence of antiarrhythmic drug therapy. We hypothesized that the cycle length of right atrial isthmus dependent flutter would correlate with right atrial cross-sectional area measurements. METHODS 60 patients who underwent ablation for electrophysiologically proven isthmus dependent right atrial flutter, who were not on Class I ...

متن کامل

Risk factors for recurrence of atrial fibrillation in patients undergoing hybrid therapy for antiarrhythmic drug-induced atrial flutter.

AIMS Catheter ablation of the inferior vena cava-tricuspid annulus isthmus and continuation of antiarrhythmic drug therapy have been shown to be an effective hybrid therapy for atrial flutter which results from antiarrhythmic drug treatment of atrial fibrillation. The aim of this study was to determine the risk factors for recurrence of atrial fibrillation in patients undergoing hybrid therapy ...

متن کامل

The Effects of a Bidirectional Cavo-Tricuspid Isthmus Block in Persistent Atrial Fibrillation

PURPOSE Hybrid therapy with catheter ablation of the cavo-tricuspid isthmus (CTI) and continuation of anti-arrhythmic drugs (AAD), or electrical cardioversion with AADs might be alternative treatments for patients with persistent atrial fibrillation (AF). The goal of study was to assess the long term success rate of hybrid therapy for persistent AF compared to antiarrhythmic medication therapy ...

متن کامل

A classification of atrial flutter and regular atrial tachycardia according to electrophysiological mechanisms and anatomical bases. A Statement from a Joint Expert Group from the Working Group of Arrhythmias of the European Society of Cardiology and the

Current classifications of regular atrial tachycardias have been based exclusively on the ECG. Differentiation between atrial flutter and atrial tachycardia depends on a rate cut-off around 240–250/min and the presence of isoelectric baselines between atrial deflections in atrial tachycardia, but not in atrial flutter. However, atrial tachycardia mechanisms, defined by electrophysiological stud...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Heart

دوره 85 4  شماره 

صفحات  -

تاریخ انتشار 2001