Development and validation of an LC-MS/MS method for pharmacokinetic study of methoxyamine in phase I clinical trial.
نویسندگان
چکیده
Methoxyamine (MX) is the first DNA base-excision-repair (BER) inhibitor evaluated in humans. This work described the development and validation of an LC-MS/MS method for quantitative determination of MX in human plasma. In this method, MX and its stable isotope methoxyl-d(3)-amine (MX-d3 as internal standard) were directly derivatized in human plasma with 4-(N,N-diethylamino)benzaldehyde. The derivatized MX and IS were extracted by methyl-tert-butyl ether, and separated isocratically on a Xterra C18 column (2.1 mm × 100 mm) using an aqueous mobile phase containing 45% acetonitrile and 0.4% formic acid at a flow rate of 0.200 ml/min. Quantitation of MX was carried out by multiple-reaction-monitoring (MRM) mode of positive turbo-ion-spray tandem mass spectrometry. This method has been validated according to FDA guidelines for bioanalytical method. The linear calibration range for MX was 1.25-500 ng/ml in human plasma with a correlation coefficient≥0.9993. The intra- and inter-assay precision (%CV) at three concentration levels (3.50, 45.0 and 450 ng/ml) ranged 0.9-1% and 0.8-3%, respectively. The stability studies showed that MX met the acceptable criteria under all tested conditions. The method developed had been applied to the determination of plasma MX concentrations in the first-in-human phase I clinical trial, and PK data were presented.
منابع مشابه
Development and Validation of Bioanalytical Method for Simultaneous Estimation of Nebivolol Enantiomers in Human Plasma Using Liquid Chromatography-tandem Mass Spectrometry
The present study describes a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of S-RRR and R-SSS nebivolol (nebivolol enantiomers) in human plasma using solid phase extraction technique. Method of both S-RRR and R-SSS nebivolol (nebivolol enantiomers) has been developed and validated using racemic nebivolol D4 as an internal standard. Analytes...
متن کاملMethod validation of methotrexate in human plasma by LC-MS technique in patients with brain tumor.
Background and aims: A selective and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been established for determination of methotrexate in human plasma. Methods: Methotrexate was extracted from plasma with acetonitrile. The mobile phase consisted of acetonitrile-water-formic acid 74: 25: 1(v/v). Twenty...
متن کاملA quick and Sensitive Liquid Chromatography–tandem Mass Spectrometry (LC-MS) Method for the Determination of Enalapril and Enalaprilat in Human Plasma: Application to a Bioequivalence Study
A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method for the estimation of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode was operated under the multiple-reaction monitoring mode. Sample pretreatment involved in a one-step protein precipitat...
متن کاملIdentification of phenolic antioxidants in Ipomoea mauritiana jacq. using spectrophotometric and mass spectroscopic studies
Objective: Ipomoea mauritiana is used in both Ayurveda and folk medicine systems. The tuberous roots are known to be diuretic, depurative, carminative, and anthelmintic. The objective of the current study was to identify phenolic antioxidants from I. mauritiana using spectrophotometric and LC-MS analysis. Materials and Methods: An activity-guided fractionation and purification process was used t...
متن کاملMethod validation of clonidine hydrochloride in human plasma by LC-MS technique
A simple and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been evaluated for the assignment of clonidine hydrochloride in human plasma. The mobile phase composed of acetonitrile–water 60:40 (v/v), and 0.2% formic acid 20 µL of sample was chromatographically analyzed using a repacked ZORBAX-XDB-ODS C18 column (2.1 mm×30 m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatography. B, Analytical technologies in the biomedical and life sciences
دوره 901 شماره
صفحات -
تاریخ انتشار 2012