Visceral arterial compromise during intra-aortic balloon counterpulsation therapy.
نویسندگان
چکیده
BACKGROUND Intraaortic balloon pump (IABP) therapy is a widely used method of circulatory support. Based on frequent findings of balloon malposition with visceral arterial compromise on computerized tomographic (CT) imaging studies, we conducted a systematic review of cardiac surgical IABP patients with available CT scans to determine reasons, incidence, and clinical relevance of malposition. METHODS AND RESULTS From January 2007 to March 2009, a total of 621 of 7756 cardiac surgical patients (8.0%) received perioperative IABP support, of whom 63 (10.1%) received a thoracoabdominal CT scan during IABP support. Proximal and distal balloon positions were analyzed. The anatomic distance from the left subclavian artery to celiac trunk and aortic transverse diameter were measured in all patients and compared with implanted balloon dimensions. Mean age was 67.1±11.9 years; 33.3% were female, and height was 169±9 cm. Based on radiography, proximal balloon position was correct in 96.8% but only appropriate in 38.1% based on CT. In 61 of 63 patients, compromise of at least 1 visceral artery was found: celiac trunk, 96.8%; superior mesenteric artery, 87.3%; and renal arteries, 66.7%. Left subclavian artery to celiac trunk distance was 241±23 mm, and balloon length was 248±17 mm and corresponded to an anatomic to balloon length mismatch in 68.2%. Spinal deformations were found in 42.9%. Laparotomy for mesenteric ischemia was required in 23.8%. Hospital mortality rate was 60.3%. CONCLUSIONS IABP malposition was commonly identified by CT. Reasons included incorrect proximal balloon position as well as an anatomic-to-balloon length mismatch. Thus, shorter than recommended balloon sizes and better positioning strategies had to be considered.
منابع مشابه
Systematic review: Intra-aortic balloon counterpulsation pump therapy: a critical appraisal of the evidence for patients with acute myocardial infarction
Introduction Intra-aortic balloon counterpulsation pump (IABP) therapy has been used in several clinical situations, predominantly in critically ill patients, since 1968 [1]. In acute myocardial infarction (AMI) patients who are experiencing continued ischemia, IABP therapy may be used in an attempt to improve patency of an infarct-related coronary artery (IRA) and reduce the rates of recurrent...
متن کاملPrevention of Possible Embolus Following Intra Aortic Balloon Counterpulsation (IABP) Insertion by Transesophageal Echocardiography ( TEE )
Severe atherosclerosis of the descending aorta is directly related to atheroembolic events. Transesophageal echocardiography (TEE) is a sensitive technique for evaluating such atheroma plaques of the thoracic aorta which may predict the risk of emboli. We describe a patient with severe intraluminal aortic atherosclerotic plaques detected by TEE while positioning an Intraaortic Balloon Counterpu...
متن کاملParaplegia associated with intraaortic balloon pump counterpulsation.
Two patients developed paraplegia associated with the use of the intraaortic balloon pump. In one patient, transient spinal ischemic episodes ceased after removal of the intraaortic balloon and the second patient apparently sustained spinal cord infarction. Possible etiologic mechanisms include vascular occlusion due to balloon position, arterial spasm, thromboembolic phenomena, hypotension, hy...
متن کاملIntraaortic Balloon Pump Counterpulsation and Cerebral Autoregulation: an observational study
BACKGROUND The use of Intra-aortic counterpulsation is a well established supportive therapy for patients in cardiac failure or after cardiac surgery. Blood pressure variations induced by counterpulsation are transmitted to the cerebral arteries, challenging cerebral autoregulatory mechanisms in order to maintain a stable cerebral blood flow. This study aims to assess the effects on cerebral au...
متن کاملPrevention of balloon damage during initiation of intra-aortic balloon counterpulsation.
Damage to an intra-aortic balloon occurred on two occasions in 93 insertion procedures. The complication was recognized before gas embolization occurred, and neither patient suffered ill effects. On both occasions the balloon was holed when pinched by artery forceps applied to the 'dacron' graft.