Measurement precision in the optimization of cardiac resynchronization therapy.

نویسندگان

  • Robert G Turcott
  • Ronald M Witteles
  • Paul J Wang
  • Randall H Vagelos
  • Michael B Fowler
  • Euan A Ashley
چکیده

BACKGROUND Cardiac resynchronization therapy improves morbidity and mortality in appropriately selected patients. Whether atrioventricular (AV) and interventricular (VV) pacing interval optimization confers further clinical improvement remains unclear. A variety of techniques are used to estimate optimum AV/VV intervals; however, the precision of their estimates and the ramifications of an imprecise estimate have not been characterized previously. METHODS AND RESULTS An objective methodology for quantifying the precision of estimated optimum AV/VV intervals was developed, allowing physiologic effects to be distinguished from measurement variability. Optimization using multiple conventional techniques was conducted in individual sessions with 20 patients. Measures of stroke volume and dyssynchrony were obtained using impedance cardiography and echocardiographic methods, specifically, aortic velocity-time integral, mitral velocity-time integral, A-wave truncation, and septal-posterior wall motion delay. Echocardiographic methods yielded statistically insignificant data in the majority of patients (62%-82%). In contrast, impedance cardiography yielded statistically significant results in 84% and 75% of patients for AV and VV interval optimization, respectively. Individual cases demonstrated that accepting a plausible but statistically insignificant estimated optimum AV or VV interval can result in worse cardiac function than default values. CONCLUSIONS Consideration of statistical significance is critical for validating clinical optimization data in individual patients and for comparing competing optimization techniques. Accepting an estimated optimum without knowledge of its precision can result in worse cardiac function than default settings and a misinterpretation of observed changes over time. In this study, only impedance cardiography yielded statistically significant AV and VV interval optimization data in the majority of patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Precision of a Parabolic Optimum Calculated from Noisy Biological Data, and Implications for Quantitative Optimization of Biventricular Pacemakers (Cardiac Resynchronization Therapy)

In patients with heart failure and disordered intracardiac conduction of activation, doctors implant a biventricular pacemaker (“cardiac resynchronization therapy”, CRT) to allow adjustment of the relative timings of activation of parts of the heart. The process of selecting the pacemaker timings that maximize cardiac function is called “optimization”. Although optimization—more than any other ...

متن کامل

Clinical impact of increasing left ventricular pacing output in cardiac resynchronization therapy – the new optimization strategy

We report a patient who did not improve after standard optimization of atrioventricular and intraventricular pacing timing, but showed response to cardiac resynchronization therapy (CRT) after increasing left ventricular (LV) pacing output. Increasing LV pacing output is one of the useful optimization methods for CRT nonresponder.

متن کامل

Echocardiography in cardiac resynchronization therapy.

Cardiac resynchronization therapy has been an effective option in patients with advanced heart failure. However, 20 to 30% of the patients do not benefit from this therapy. Clinical, electrocardiographic and echocardiographic criteria have been studied in an attempt to select patients who will benefit from a cardiac resynchronization therapy, and the echocardiogram is important both in the sele...

متن کامل

The role of echocardiography in cardiac resynchronization therapy.

Echocardiography is the most important imaging tool for managing heart failure patients. With the advent of cardiac resynchronization therapy (CRT), its role has been broadened by data pertaining to patient selection, optimization of device settings, and outcome assessment. Beyond ejection fraction determination, echocardiographic methods that measure tissue velocity and strain may have the cap...

متن کامل

An Overview of Current Cardiac Resynchronization Therapy.

UNLABELLED Cardiac resynchronization therapy (CRT) is currently an established device therapy for heart failure (HF) patients. Existing knowledge of implantation techniques, advances in device-based technologies and clinical trial experience have all significantly impacted this evolving therapy in recent years. This review article will address the updated CRT guidelines, and potentially new ind...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Heart failure

دوره 3 3  شماره 

صفحات  -

تاریخ انتشار 2010