Electrochemical assay system with single-use electrode strip for measuring lactate in whole blood.

نویسندگان

  • N Shimojo
  • K Naka
  • H Uenoyama
  • K Hamamoto
  • K Yoshioka
  • K Okuda
چکیده

We have developed an assay system for measuring lactate in whole blood, consisting of a single-use strip of an enzyme-coated electrode and a small meter. The electrode strip is made of three plastic films: a cover sheet, a spacer, and an insulation layer printed with electrodes that are coated with lactate oxidase (EC 1.1.3.x) and ferricyanide as an electron mediator. The meter measures the magnitude of the anodic current of the reduced mediator by the enzymatic reaction and displays the lactate concentration 60 s after a blood sample (5 microL) is applied. The calibration curve was linear up to 20 mmol/L, and the between-run CVs at three concentrations were 1.7-8.4%. Lactate concentrations determined by this method (y) in blood samples from healthy individuals before and after exercise agreed with the results obtained by the conventional enzymatic method (x): y = 0.97x - 0.3, Sy/x = 0.7. This assay provides a rapid and convenient test for measuring blood lactate concentrations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monitoring thrombin generation by electrochemistry: development of an amperometric biosensor screening test for plasma and whole blood.

BACKGROUND Complete investigation of thrombophilic or hemorrhagic clinical presentations is a time-, apparatus-, and cost-intensive process. Sensitive screening tests for characterizing the overall function of the hemostatic system, or defined parts of it, would be very useful. For this purpose, we are developing an electrochemical biosensor system that allows measurement of thrombin generation...

متن کامل

Disposable single-use electrochemical sensor: A novel hollow fiber based tool for environmental monitoring of cadmium

The objective of this study is to design a simple, fast, sensitive and single-use electrode with the simultaneous capability of preconcentration and measuring, for application in a three-electrode voltammetry system to identify and measure the heavy metal cadmium. The design process of this sensor consists of several stages. The polyurethane foam and multi walled carbon nanotubes nanoparticles ...

متن کامل

Test-strip method for measuring lactate in whole blood.

We have developed a dry reagent strip system for measuring lactate in whole blood. The test strip contains lactate oxidase (no EC number assigned), horseradish peroxidase (EC 1.11.1.7), and N-ethyl-N-(2-hydroxy-3-sulfopropyl)-m-toluidine. The system is designed to measure with a reflectometer the color that developed in the test strip, although the lactate concentration can be estimated without...

متن کامل

Hematocrit compensation in electrochemical blood glucose monitoring systems.

BACKGROUND Hematocrit (Hct) is a common interferent in test strips used by diabetes patients to self-monitor blood glucose (BG), resulting in measurement bias. Described is an electrochemical BG monitoring system (OneTouch(®) Verio™) that uses a cofacial sensor design, soluble enzyme chemistry, and multiphasic waveform to effectively correct for patient Hct, delivering an accurate reading for w...

متن کامل

Sodium dodecyl sulfate-polyacrylamide gel electrophoresis of urine: concentration of urinary proteins by precipitation with coomassie blue.

blood offers the advantage of easy handling of samples without the need for immediate deproteinization and centrifugation (4,5). The test-strip method also provides rapid and precise measurements of lactate concentrations in whole blood (7). An amperometric assay of blood glucose with a ferrocene-mediated enzyme electrode has been developed and used to assay blood glucose with a single-use elec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 39 11 Pt 1  شماره 

صفحات  -

تاریخ انتشار 1993