Heat Transfer Measurements Using Thin Film Gauges and Infrared Thermography on a Film Cooled Transonic Vane

نویسنده

  • Colin J. Reagle
چکیده

This work presents a comparison of thin film gauge (TFG) and infrared (IR) thermography measurement techniques to simultaneously determine heat transfer coefficient and film cooling effectiveness. The first comparison was with an uncooled vane where heat transfer coefficient was measured at Mex=0.77 and Tu=16%. Relatively good agreement was found between the results of the two methods and the effect of recovery temperature and data reduction time was analyzed. Improvements were made to the experimental set up for the next comparison, a showerhead film cooled vane. This geometry was tested at BR=0, 2.0, Mex=0.76 and Tu=16%. The TFG and IR results did not compare well for heat transfer coefficient or film cooling effectiveness. The effects of measured and calculated recovery temperature were analyzed as well as the respective data reduction methods, though the analysis could not account for the effectiveness trend seen on the suction surface. Finally, a vane with showerhead and shaped film cooling holes were presented at BR=0, 1.7, 2.0, 2.8, Mex=0.85, and Tu=13% to assess a new film cooling geometry measured with the IR technique. Similarities on the suction surface trend between the different film cooled geometries tested with IR indicate a flaw in the experiment that will require further analysis, changes and testing to complete the comparison with TFG.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of a Showerhead and Shaped Hole Film Cooled Vane at High Freestream Turbulence and Transonic Conditions

An experimental study was performed to measure surface Nusselt number and film cooling effectiveness on a film cooled first stage nozzle guide vane using a transient thin film gauge (TFG) technique. The information presented attempts to further characterize the performance of shaped hole film cooling by taking measurements on a row of shaped holes downstream of leading edge showerhead injection...

متن کامل

Microscale Temperature Measurements near the Contact Line of an Evaporating Thin Film in a V-Groove

Thin-film evaporation of heptane in a V-groove geometry is experimentally investigated. The groove is made of fused quartz, and electrical heating of a thin layer of titanium coated on the backside of the quartz substrate provides a constant heat flux. The effects of liquid feeding rate on the temperature suppression in the thin-film region and on the meniscus shape are explored. High resolutio...

متن کامل

Temperature measurements near the contact line of an evaporating meniscus V-groove

Evaporation from a meniscus of heptane liquid in a V-groove geometry is experimentally investigated. A thin layer of titanium coated on the backside of the fused quartz groove is electrically heated to provide a constant heat flux. The temperature profile in the evaporating thin film region of the extended meniscus is measured using high-resolution infrared thermography and the temperature supp...

متن کامل

Instabilities of Thin Viscous Liquid Film Flowing down a Uniformly Heated Inclined Plane

Instabilities of a thin viscous film flowing down a uniformly heated plane are investigated in this study. The heating generates a surface tension gradient that induces thermocapillary stresses on the free surface. Thus, the film is not only influenced by gravity and mean surface tension but also the thermocapillary force is acting on the free surface. Moreover, the heat transfer at the free su...

متن کامل

Synthesis, Characterization, and Application of Zr,Ce-TiO2/SiO2 Nanocomposite Thin Film as Visible-light Active Photocatalyst

A novel Zr,Ce-TiO2/SiO2 nanocomposite thin film was successfully prepared with various amounts of Zr4+ and Ce4+ as codopant ions for self-cleaning applications. A thin film was coated on a tile substrate by dip-coating and porous Zr,Ce-TiO2/SiO2 was obtained after heat treatment for 2 hours at 500 °C. The SEM images an...