Approach for multi - period PD calibration for LDP portfolios

نویسنده

  • Rainer Glaser
چکیده

In the paper we propose PD calibration framework for LDP that allows producing smooth non-zero PD estimates for any given time horizon within the length of economic cycle. The advantages of the approach is that produced PDs are consistent with two main anchors – PIT and TTC PD estimates and are subject to smooth, monotonic transition between those two anchors. In practise, proposed framework could be applied to risk-based pricing of mid-term deals, whose duration is too long compared with PIT PD horizon and significantly shorter that the length of the whole economic cycle.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multi-period and Multi-objective Stock Selection Optimization Model Based on Fuzzy Interval Approach

The optimization of investment portfolios is the most important topic in financial decision making, and many relevant models can be found in the literature.  According to importance of portfolio optimization in this paper, deals with novel solution approaches to solve new developed portfolio optimization model. Contrary to previous work, the uncertainty of future retur...

متن کامل

Calibration of Hardening Rules for Cyclic Plasticity

In the realm of multi-axial ratcheting, a step by step mathematical approach is developed for the parameter determination of decomposed kinematic hardening rules. For this purpose, key characteristics are mathematically derived for these hardening rules under multi-axial loading. These characteristics are then utilized to develop expressions which relate the loading history to the accumulated p...

متن کامل

Comparison of Single- site and Multi-site Based Calibrations of SWAT in Taleghan Watershed, Iran

Calibration of model is critical for hydrologic modeling of large watersheds in a mountain watershed. In this study Soil and Water Assessment Tool (SWAT) used to comparison a single-site calibration procedure that employed streamflow measurement at outlet of watershed to a multi-site calibration method that used streamflow measurements at three stations (Galinak, Joestan and Dehdar). Results sh...

متن کامل

Automatic Calibration of HEC-HMS Model Using Multi-Objective Fuzzy Optimal Models

Estimation of parameters of a hydrologic model is undertaken using a procedure called “calibration” in order to obtain predictions as close as possible to observed values. This study aimed to use the particle swarm optimization (PSO) algorithm for automatic calibration of the HEC-HMS hydrologic model, which includes a library of different event-based models for simulating the rainfall-runoff pr...

متن کامل

Low-Energy Deuteron Polarimeter

We built a Low Energy Deuteron Polarimeter (LDP) which measures the spin-polarization of deuteron beams in the energy range of 25 to 80 keV. The LDP works by measuring azimuthal asymmetries in the D(~ d, n)He reaction at θlab = 90 ◦ and comparing them to analyzing powers. We built this polarimeter for two reasons. Firstly, to crosscheck other polarimeters at KVI (LSP and IBP). Secondly to test ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013