Accuracy of cerebral monitoring in detecting cerebral ischemia during carotid endarterectomy: a comparison of transcranial Doppler sonography, near-infrared spectroscopy, stump pressure, and somatosensory evoked potentials.

نویسندگان

  • Stefan Moritz
  • Piotr Kasprzak
  • Matthias Arlt
  • Kai Taeger
  • Christoph Metz
چکیده

BACKGROUND This study compares the accuracy of cerebral monitoring systems in detecting cerebral ischemia during carotid endarterectomy. METHODS The authors compared transcranial Doppler sonography (TCD), near-infrared spectroscopy (NIRS), stump pressure (SP) measurement, and somatosensory evoked potentials (SEP) in 48 patients undergoing carotid surgery during regional anesthesia. Cerebral ischemia was assumed when neurologic deterioration occurred. During clamping, the minimum mean middle cerebral artery velocity (TCD(min)), its percentage change (TCD%), the minimum regional saturation of oxygen (NIRS(min)), its percentage change (NIRS%), the mean SP, and the changes of SEP amplitude were recorded. To analyze the corresponding sensitivity and specificity of each parameter, the authors performed receiver operating characteristic analysis. RESULTS Neurologic deterioration occurred in 12 patients. SP and NIRS were successfully performed in all patients. TCD monitoring was not possible in 10 (21%); SEP was not possible in 2 patients (4%). All parameters provided the ability to distinguish between ischemic and nonischemic patients. TCD% and NIRS% showed significantly better discrimination than TCD(min) and NIRS(min) (P < 0.05). The highest area under the curve (AUC) was found for TCD% (AUC = 0.973), but there was no significant difference compared with NIRS% (AUC = 0.905) and SP (AUC = 0.925). The lowest AUC was found for SEP (AUC = 0.749), which was significantly lower than that for TCD%, NIRS%, and SP. CONCLUSIONS TCD%, NIRS%, and SP measurement provide similar accuracy for the detection of cerebral ischemia during carotid surgery. Lower accuracy was found for SEP monitoring. Because of the high rate of technical difficulties (21%), TCD monitoring was the least practical of the investigated monitoring devices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monitoring cerebral ischemia during carotid endarterectomy and stenting

Current therapy for carotid stenosis mainly includes carotid endarterectomy and endovascular stenting, which may incur procedure-related cerebral ischemia. Several methods have been employed for monitoring cerebral ischemia during surgery, such as awake neurocognitive assessment, electroencephalography, evoked potentials, transcranial Doppler, carotid stump pressure, and near infrared spectrosc...

متن کامل

Comparison of near-infrared spectroscopy and somatosensory evoked potentials for the detection of cerebral ischemia during carotid endarterectomy.

BACKGROUND AND PURPOSE We sought to assess the clinical value of regional cerebral saturation (rSO2) obtained by means of the cerebral oximeter INVOS 3100A (Somanetics) in comparison to monitoring of somatosensory evoked potentials (SEP) for the reliable detection of severe cerebral ischemia requiring shunt placement in the individual patient undergoing carotid surgery under general anesthesia....

متن کامل

Cerebral monitoring during carotid endarterectomy by transcranial Doppler ultrasonography

PURPOSE To evaluate the efficacy and safety of cerebral monitoring by transcranial Doppler ultrasonography (TCD) for the detection of cerebral ischemia during carotid endarterectomy (CEA). METHODS From August 2004 to December 2013, 159 CEAs were performed in a tertiary hospital. All procedures were performed under general anesthesia. Intraoperative TCD was routinely used to detect cerebral is...

متن کامل

Somatosensory evoked potentials sensitivity relative to electroencephalography for cerebral ischemia during carotid endarterectomy.

BACKGROUND AND PURPOSE The relation between electroencephalographic pattern changes and cerebral ischemia during carotid endarterectomy under general anesthesia is well established. Pattern changes seen on somatosensory evoked potentials under the same conditions are reported to be more sensitive indicators of cerebral ischemia. We estimated the sensitivity and specificity of somatosensory evok...

متن کامل

Near-Infrared Spectroscopy versus Transcranial Doppler-Based Monitoring in Carotid Endarterectomy

Background Proper monitoring of cerebral perfusion during carotid artery surgery is crucial for determining if a shunt is needed. We compared the safety and reliability of near-infrared spectroscopy (NIRS) with transcranial Doppler (TCD) for cerebral monitoring. Methods This single-center, retrospective review was conducted on patients who underwent carotid endarterectomy (CEA) using selectiv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 107 4  شماره 

صفحات  -

تاریخ انتشار 2007