Fractured neck of femur below long spinopelvic fixation for Charcot spine: a case report

نویسندگان

  • Gerald MY Quan
  • Peter Wilde
چکیده

INTRODUCTION We present a case of a patient with a previously undescribed complication: intertrochanteric femoral neck insufficiency fracture after long-segment instrumented spinopelvic fusion to the ilium for Charcot spine. CASE PRESENTATION A 42-year-old Caucasian man with post-traumatic complete T6 paraplegia presented to our institution after developing Charcot spinal arthropathy at L3 and L4 and symptoms of autonomic dysreflexia 21 years after his original spinal cord injury. Multiple anterior and posterior surgeries were required to eventually achieve stabilization of his thoracolumbar spine to his pelvis and resolution of symptoms. The most distal fixation point was two iliac wing screws bilaterally. At 10 weeks after the final spinal surgery and after posterior spinal bony consolidation had occurred, he sustained an intertrochanteric femoral neck fracture, distal to the iliac fixation, whilst bending forward in his wheelchair. His proximal femoral fracture was internally fixed with an intramedullary device. CONCLUSIONS Spinal Charcot's arthropathy is a rare condition that may occur in patients with post-traumatic spinal cord injury. Although associated with high risk of complications, circumferential instrumented fusion in Charcot spine can restore spinal stability. Insufficiency fractures of the proximal femur are possible complications of long spinopelvic fusions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Perpendicular Iliac Screw Placement for Reinforcement of Spinopelvic Stabilization.

Iliac fixation is indicated to provide spinopelvic stabilization in select cases of long segment thoracolumbar spine fusion, spinal osteotomy/realignment, trauma, and instability caused by tumor or infection. Traditional iliac fixation with iliac screws or S2 alar/iliac (S2AI) screws may provide inadequate fixation in select clinical scenarios, such as severely compromised bone quality or spino...

متن کامل

Bilateral Simultaneous Femoral Neck and Shafts Fractures – A Case Report

  Simultaneous fractures of the femoral neck and shaft are not common injuries, though they cannot be considered rare. Herein, we report our experience with a patient with bilateral occurance of this injury. Up to the best of our knowkedge this is the first case reported in literature in which correct diagnosis was made initially. Both femurs were fixed using broad 4.5 mm dynamic compression pl...

متن کامل

Educational view of Pathological Fracture of Femur due to Hydatid Cysts: A Case Report and Review of Literature

Hydatid cysts can be caused by Echinococcus species in various tissues. Skeletal cystic lesions are very rare and may be neglected. Here, we report a case of pathologic fracture following primary hydatid cystic lesions in the proximal and femoral shaft bone. A 62-year-old man suffered a sudden fracture followed by swelling of the thigh. Intramedullary femoral fixation was made and during the su...

متن کامل

Cementless Total Hip Arthroplasty After an Iatrogenic Subtrochanteric Fracture due to Hardware Removal: A Case Report

Introduction: Total hip arthroplasty (THA) after proximal femoral fixation is a challenging procedure due to possible hardware-related complications. Case presentation: A 78-year-old female with hip osteoarthritis had a proximal femoral osteotomy fixed using a blade plate in the same femur 41 years ago. A two-step approach was planned. After a challenging...

متن کامل

A comparative analysis of the efficacy of short-segment pedicle screw fixation with that of long-segment pedicle screw fixation for unstable thoracolumbar spinal burst fractures

The indications for operative treatment and type of stabilization procedures for the treatment of thoracolumbar burst fracture remain controversial. As surgical reconstruction for the thoracolumbar burst fracture, both long-segment pedicle screw fixation and short-segment pedicle screw fixation including fractured vertebral body have been used widely. The present study evaluated the efficacy of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2013