Intra-rater reliability and agreement of muscle strength, power and functional performance measures in patients with hip osteoarthritis.
نویسندگان
چکیده
OBJECTIVE To investigate the reliability and agreement of measures of lower extremity muscle strength, power and functional performance in patients with hip osteoarthritis at different time intervals, and to compare these with the same measures in healthy peers. DESIGN Intra-rater test-retest separated by 1, 2, or 2.5 weeks in patients, and 1 week in healthy peers. SUBJECTS Patients with hip osteoarthritis (age range 61-83 years) with 1 (n = 37), 2 (n = 35), or 2.5 weeks (n = 15) between tests, and 35 healthy peers (age range 63-82 years). METHODS Maximal isometric hip and thigh strength, leg extensor power, and functional performance (8-foot Up & Go, stair climbing, chair stand and 6-min walk) were measured in patients, and quadriceps strength, leg extensor power and functional performance were measured in healthy peers. Systematic error, reliability and agreement were calculated. RESULTS Most hip strength measurements for the most symptomatic extremity, and nearly all strength measurements for the least symptomatic lower extremity, declined after 1 week (p < 0.05), but not after a 2.5-week interval. In healthy peers, quadriceps strength was unchanged. Regardless of the time interval, leg extensor power was unchanged, while functional performances improved at retest for all participants. CONCLUSION In patients with hip osteoarthritis leg extensor power is unaffected by the time interval between tests, in contrast to muscle strength and functional performance.
منابع مشابه
Intra- and Inter-Rater Reliability of Micro Manual Muscle Tester of the Lower Extremity in Children With Diplegia Cerebral Palsy
Objectives: The Micro Manual Muscle Tester (MMMT) is a Hand-Held Dynamometer (HHD). The current study aimed to evaluate the intra- and inter-rater reliability of this device. Methods: To determine the reliability of the MMMT, two previously trained assessors to work with HHD performed HHD measurements on 7 muscle groups of the lower extremities (hip flexors, hip extensors, hip abductors, knee ...
متن کاملReproducibility of range of motion and muscle strength measurements in patients with hip osteoarthritis – an inter-rater study
BACKGROUND Assessment of range of motion (ROM) and muscle strength is fundamental in the clinical diagnosis of hip osteoarthritis (OA) but reproducibility of these measurements has mostly involved clinicians from secondary care and has rarely reported agreement parameters. Therefore, the primary objective of the study was to determine the inter-rater reproducibility of ROM and muscle strength m...
متن کاملFunctional Movement Screen in Elite Boy Basketball Players: A Reliability Study
Purpose: To investigate the reliability of Functional Movement Screen (FMS) in basketball players. A few studies have compared the reliability of FMS between raters with different experience in athletes. The purpose of this study was to compare the FMS scoring between the beginners and expert raters using video records. Methods: This is a cross-sectional study. The study subjects compris...
متن کاملComparison of the Effect of 8 Weeks of Land Exercise Therapy and Hydrotherapy on Functional Activities of Elderly Women with Knee Osteoarthritis
Objectives: Knee osteoarthritis is one of the most common musculoskeletal problems in older adults. Pain, stiffness, tenderness, decreased muscle strength and joint range of motion, impaired proprioception, and balance problems lead to impaired physical function, making the person incapable of performing functional activities. Therefore, it is necessary to use strategies to control and reduce t...
متن کاملIntra-rater reliability of sonographic measurement of the upper trapezius, supraspinatus and deltoid muscles in women with frozen shoulder and healthy women
Background: Some studies show that frozen shoulder is due to the pathologic changes in the muscles around the shoulder. Measurement of the ultrasonic thickness of a muscle is a method for measuring the muscle changes. There is no study about the reliability of measurement of the muscle’s ultrasonic thickness around the shoulder in patients with frozen shoulder. The present study aims to invest...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of rehabilitation medicine
دوره 46 10 شماره
صفحات -
تاریخ انتشار 2014