Shrinkage stress and degree of conversion of a dental composite submitted to different photoactivation protocols.

نویسندگان

  • Karla M C Oliveira
  • Ailla C R A Lancellotti
  • Renzo A Ccahuana-Vásquez
  • Simonides Consani
چکیده

The aim of this study was to evaluate the polymerization stress and degree of conversion of a composite submitted to different photoactivation protocols. The composite Filtek Z350 was placed in the central perforation of a photoelastic disc and polymerized using a LED-based curing unit (BluePhase II--Ivoclar Vivadent) with energy density of 12, 24 or 36 J/cm2 using the following photopolymerization protocols: continuous high intensity (HI: 1200 mW/cm2 during 10, 20 or 30s), continuous low intensity (LI: 650 mW/cmz during 18, 36 or 54s) and soft-start (SS: 150 mW/cm2 during 5 s + 1200 mW/cm2 during 9, 19 or 29s) (n = 5). Photoelastic analysis was used to evaluate polymerization shrinkage stress and FTIR was performed to determine the degree of conversion of the composite. ANOVA 3-way procedure was used to determine the significance of the main effects and their interactions followed by two-way ANOVA for each time was performed (p < 0.05). Shrinkage stress increased with higher values of energy. No statistically significant differences on polymerization shrinkage stress were found between high and low intensity activation modes. Soft-start method generated stresses that were statistically lower than continuous modes except when 12 J/cm2 was applied. Similar degree of conversion was observed for photoactivation modes used, except for soft-start mode with 12, 24 and 36J/cm2 that showed lowest levels of conversion. Energy density and activation mode influenced polymerization shrinkage stress, but no benefit on degree of conversion was observed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

اندازه گیری میزان انقباض پلیمریزاسیون خطی در کامپوزیت ایرانی ایده آل ماکو (IDM) لایت کیور

 Polymerization shrinkage of light cure composite resins causes many complications in conservative and esthetic restorations. The objective of this in-vitro study was to evaluate the polymerization shrinkage, degree of conversion and the amount of filler in IDM and tetric ceram composites. Ten disk shaped, uncured specimens (8mm×1.547mm) of each composite were placed on glass slide in the cente...

متن کامل

Effect of Three Light Curing Protocols and Load Cycling on Microleakage of Class V Composite Restorations

  Objective: Different methods have been suggested to overcome the polymerization shrinkage of composite restorations. Changing the light curing protocol to improve polymerization by using new light curing units is among these methods. The new devices are more efficient, portable and durable and produce less heat. This study aimed to assess the marginal microleakage of class V composite restora...

متن کامل

Post-curing conversion kinetics as functions of the irradiation time and increment thickness

OBJECTIVE This study evaluated the variation of conversion degree (DC) in the 12 hours following initial photoactivation of a low-shrinkage composite resin (Venus Diamond). MATERIAL AND METHODS The conversion degree was monitored for 12 hours using Attenuated Total Reflection (ATR) F-TIR Spectroscopy. The composite was placed in 1 or 2 mm rings and cured for 10 or 20 seconds with a LED lamp. ...

متن کامل

Effect of Light Intensity and Irradiation Time on the Polymerization Process of a Dental Composite Resin

Polymerization shrinkage is a critical factor affecting the longevity and acceptability of dental composite resins. The aim of this work was to evaluate the effect of light intensity and irradiation time on the polymerization process of a photo cured dental composite resin by measuring the Vickers hardness number (VHN) and the volumetric polymerization shrinkage. Samples were prepared using a d...

متن کامل

Pre-heating of high-viscosity bulk-fill resin composites: effects on shrinkage force and monomer conversion.

OBJECTIVES To investigate the influence of pre-heating of high-viscosity bulk-fill composite materials on their degree of conversion and shrinkage force formation. METHODS Four bulk-fill composite materials (Tetric EvoCeram Bulk Fill-TECBF, x-tra fil-XF, QuixFil-QF, SonicFill-SF) and one conventional nano-hybrid resin composite (Tetric EvoCeram-TEC) were used. The test materials were either k...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta odontologica latinoamericana : AOL

دوره 25 1  شماره 

صفحات  -

تاریخ انتشار 2012