Spherical Aberration of Intraocular Lenses
نویسنده
چکیده
Advancements in cataract surgery and intraocular lens (IOL) design have optimized the postoperative optical performance of the pseudophakic eye. One of the recent spotlights of IOL design has been formulating optical properties similar to a clear, young lens and addressing spherical aberration. Spherical aberration in the human eye is a combination of the positive spherical aberration of the cornea,1-3 and the negative spherical aberration of the crystalline lens.4,5 In young eyes, the positive spherical aberration of the cornea is compensated by the negative spherical aberration of the lens; as a result, overall spherical aberration in the young eye is low.2,3,6 As the eye ages, the optical properties of the crystalline lens change,4,7 resulting in overall positive spherical aberration2,8,9 and decreased optical performance. Spherical aberrations generally reduce the contrast of the retinal image10,11 and affect visual performance, especially under mesopic conditions.12 Conventional spherical IOLs increase the positive spherical aberration in the eye following cataract extraction.13,14 In 2002, an aspheric IOL design was introduced to compensate for the positive spherical aberration of the cornea.15 Aspheric IOLs have been designed with an anterior prolate suface (Tecnis, Advanced Medical Optics), a posterior prolate surface (Acrysof IQ, Alcon Laboratories), or with both anterior and posterior prolate surfaces (Akreos AO, SofPort AO and L161 AO, Bausch & Lomb) and compensate for corneal spherical aberration to varying degrees. In this issue of JOVR, a double-blind randomized controlled trial conducted by Jafarinasab et al16 compares spherical aberration and contrast sensitivity among 3 different types of aspheric IOLs (Tecnis, Akreos AO, and Acrysof IQ) and one spherical IOL (Sensar). Significantly higher spherical aberration was reported with the spherical IOL and the zeroaberration aspheric IOL as compered to the negative aberration aspheric IOLs, however this advantage was pupil-size dependent. With increased pupil size from 4 to 6 mm, an increase in spherical aberration was observed for all four types of IOLs, however significantly more with the spherical IOL. Contrast sensitivity function under mesopic conditions and at low spatial frequencies (1.5 to 3 cpd) was significantly higher in the Tecnis group as compared to the others. At higher spatial frequencies (12 to 18 cpd), Acrysof IQ worked significantly better. The authors concluded that the performance of aspheric IOLs is pupil dependent and that their function deteriorates to some extent under mesopic conditions, as there was no significant difference between spherical and aspheric IOLs in mesopic contrast sensitivity at 6 cpd. Although this study is a well-designed clinical trial with interesting results, the readers should keep in mind that the best way to compare two groups with analysis of variance (ANOVA) is using post hoc tests such as Bonferroni adjustment of type one error. This is one of the reasons for discrepancies in the results among different studies. Another explanation could be different measurement protocols. There are several studies comparing different types of spherical and aspheric IOLs under various conditions and with varying protocols. The readers should be careful about applying the results and accepting them as general rules.
منابع مشابه
Extended depth of focus with induced spherical aberration in light-adjustable intraocular lenses.
PURPOSE To evaluate the quality of vision and depth of focus induced by controlled amounts of negative spherical aberration in patients implanted bilaterally with light-adjustable intraocular lenses. DESIGN Prospective, nonrandomized clinical trial. METHODS Seventeen patients were implanted and treated with appropriate spatial irradiance light profiles. One eye was set for emmetropia, and t...
متن کاملEvaluation of actual retinal images produced by misaligned aspheric intraocular lenses in a model eye
PURPOSE To examine the effect of misalignment (decentration and tilt) of intraocular lenses (IOLs) on retinal image quality using a water-immersed model eye with corneal spherical aberration adjusted to the values found in normal human eyes (spherical aberration 0.25 μm; pupil diameter 6 mm). METHODS Three types of IOL holders were prepared. The first was without decentration or tilt, the sec...
متن کاملAdaptive optics simulation of intraocular lenses with modified spherical aberration.
PURPOSE Adaptive optics systems can be used to investigate the potential visual benefit associated with correcting ocular wave-front aberration. In this study, adaptive optics techniques were used to evaluate the potential advantages and disadvantages associated with intraocular lenses (IOLs) with modified spherical aberration profiles. METHODS An adaptive optics vision simulator was construc...
متن کاملHigher order aberration comparison between two aspherical intraocular lenses: MC6125AS and Akreos advanced optics.
AIM To compare higher order aberrations in two aspherical intraocular lenses (IOLs): Akreos advanced optics (AO) and Dr. Schmidt Microcrystalline 6125 aspheric anterior surface (MC6125AS) with each other. METHODS Forty eyes of 39 patients underwent phacoemulsification and Akreos AO and MC6125AS were implanted in their eyes in a random manner. Three months post-operatively, higher order aberra...
متن کاملB&L Aspheric Lenses- the next step in IOL evolution
with a negative spherical aberration designed to compensate for positive spherical aberration found in the cornea of the typical cataract patient. However, these lenses depend on precise positioning. A small offset in centration may result in significant higher order aberrations such as coma, along with significant visual impairment. These negative spherical aberration IOLs are contra-indicated...
متن کاملHigher-order aberrations after implantation of iris-fixated rigid or foldable phakic intraocular lenses.
PURPOSE To evaluate higher-order aberrations (HOAs) after implantation of Artiflex phakic intraocular lenses (pIOLs). SETTING Department of Ophthalmology, Academic Hospital Maastricht, Maastricht, The Netherlands. METHODS This retrospective comparative case series comprised 27 eyes (14 patients) that had Artiflex pIOL implantation and 22 eyes (13 patients) that had Artisan pIOL implantation...
متن کامل