Clinical utility of two-dimensional magnetic resonance angiography in detecting coronary artery disease.

نویسندگان

  • J C Post
  • A C van Rossum
  • M B Hofman
  • C C de Cock
  • J Valk
  • C A Visser
چکیده

AIMS The accuracy of magnetic resonance angiography in detecting proximal coronary artery stenoses is unclear. We postulated that fast magnetic resonance angiography is capable of (1) imaging proximal coronary arteries, and (2) detecting stenoses of > or = 50% of their luminal diameter. METHODS AND RESULTS Thirty-five patients, referred for analysis of angina pectoris, underwent both conventional angiography and magnetic resonance angiography of coronary arteries. A fast k-space segmented gradient-echo technique was used during breath-holds. Two observers, blinded to the results of conventional angiography, independently analysed the magnetic resonance studies for (1) length of visualized segments, and (2) presence of signal voids indicative of stenoses. From 140 proximal arteries, 15 (11%) were excluded because of incomplete imaging or degraded image quality. Mean length of the visualized segments was 9 +/- 4 mm for the left main, 62 +/- 16 mm for the left anterior descending, 21 +/- 9 mm for the left circumflex and 89 +/- 32 mm for the right coronary artery. Sensitivity for detecting > or = 50% luminal diameter stenoses was 0.00 for the left circumflex, 0.53 for the left anterior descending coronary artery, 0.71 for the RCA and 1.00 for the left main artery. Specificity varied from 0.73 for the left anterior descending coronary artery to 0.96 for the left circumflex. Inter-observer agreement was 0.90. CONCLUSION Thus, segmented magnetic resonance angiography is capable of non-invasive imaging of proximal coronary anatomy. Its good accuracy in detecting left main coronary artery disease, intermediate accuracy in detecting right coronary artery and left anterior descending coronary artery stenoses, and low accuracy in detecting left circumflex lesions fit within a range of sensitivities and specificities found by others. Further technical advances are necessary to make the technique clinically robust.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship between Late Gadolinium Enhancement Extent in Cardiac Magnetic Resonance Imaging and Severity of Coronary Artery Disease in Old Myocardial Infarction

Purpose: To assess the relationship between the severity of coronary arteries involvement and the extent and pattern of myocardial scars in Cardiac Magnetic Resonance of patients with history of remote myocardial infarction. Materials and Methods: The Cardiac Magnetic Resonance images of sixty patients with history of remote ST segment or non-ST segment elevation myocardial infarction were ...

متن کامل

August 2004 Issue.qxd

Ischemic heart disease is the leading cause of death worldwide. At present, coronary angiography is the gold standard for the diagnosis of coronary artery disease. Conventional coronary angiography is an invasive procedure with a small, yet inherent risk of myocardial infarction, stroke, potential arrhythmias, and death. Other noninvasive diagnostic tools, such as electrocardiography, echocardi...

متن کامل

Evaluation of strain and strain rate parameters using two-dimensional speckle-tracking echocardiography in patients with coronary artery disease (Research Article)

The study aimed was to measure left ventricular (LV) strain using speckle tracking echocardiography (STE) for assessment of LV function. Eighty-two subjects (mean age 57±9 years) with suspected chest pain underwent two-dimensional (2D)-echocardiography before coronary angiography. Conventional echocardiographic parameters were used for the assessment of LV function. Longitudinal strain and its ...

متن کامل

Assessment of coronary artery disease using 3.0T magnetic resonance coronary angiography: a national multicenter trial

Background 3.0T contrast enhanced whole-heart coronary magnetic resonance angiography (MRA) is a promising method for noninvasive, radiation-free detection and exclusion of obstructive coronary artery disease (CAD); however, the accuracy of this approach has not been determined in a multicenter trial. Methods An ECG-triggered, navigator-gated, inversion-recovery prepared, segmented gradient-ech...

متن کامل

Diagnostic performance of 3T stress magnetic resonance myocardial perfusion imaging (MRMPI) using 32-channel cardiac coil in patients with coronary artery disease

Background/aim With newly available 32-channel cardiac coil, 3 tesla MRI system provides increased signal-to-noise radio (SNR), reduced imaging time and improved spatial resolution. This study sought to determine the diagnostic performance of 3T stress MRMPI with 32-channel cardiac coil in detecting clinical relevant coronary artery stenosis in comparison with invasive coronary angiography (ICA).

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 18 3  شماره 

صفحات  -

تاریخ انتشار 1997