Influence of skull conductivity perturbations on EEG dipole source analysis.

نویسندگان

  • Fangmin Chen
  • Hans Hallez
  • Steven Staelens
چکیده

PURPOSE Electroencephalogram (EEG) source analysis is a noninvasive technique used in the presurgical of epilepsy. In this study, the dipole location and orientation errors due to skull conductivity perturbations were investigated in two groups of three-dimensional head models: A spherical head model and a realistic head model. METHODS In each group, the head model had a brain-to-skull conductivity ratio (Rsigma) within the range of 10-40. Solving the forward problem in the head model with skull conductivity perturbations along with the inverse problem in the baseline head model with Rsigma=20 permitted the derivation of the dipole estimation errors. RESULTS Perturbations in the skull conductivity generated dipole location and orientation errors: The larger the perturbations, the larger the errors and the error ranges. The dipole orientation error due to skull conductivity perturbations was not great (maximal mean of < 5 degrees) in this study, but the dipole location error was notable (maximal mean of > 5 mm). CONCLUSIONS Therefore, the influence of skull conductivity perturbations on EEG dipole source analysis cannot be neglected. This study suggests that it is necessary to measure the skull conductivity of the individual patients in order to achieve accurate EEG source analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Minimum-norm cortical source estimation in layered head models is robust against skull conductivity error☆☆☆

The conductivity profile of the head has a major effect on EEG signals, but unfortunately the conductivity for the most important compartment, skull, is only poorly known. In dipole modeling studies, errors in modeled skull conductivity have been considered to have a detrimental effect on EEG source estimation. However, as dipole models are very restrictive, those results cannot be generalized ...

متن کامل

Effect of Brain-to-Skull Conductivity Ratio on EEG Source Localization Accuracy

The goal of this study was to investigate the influence of the brain-to-skull conductivity ratio (BSCR) on EEG source localization accuracy. In this study, we evaluated four BSCRs: 15, 20, 25, and 80, which were mainly discussed according to the literature. The scalp EEG signals were generated by BSCR-related forward computation for each cortical dipole source. Then, for each scalp EEG measurem...

متن کامل

Influence of Volume Conductor Model Errors on EEG Dipole Source Localization in Neonates

Magnetic resonance imaging (MRI) and electroencephalography (EEG) are the most important diagnostic tools in patients with neurological disorders. Integrating both techniques for 3D localization of active sources in the brain can help physicians to better understand their generation and propagation and do direct comparison with MRI lesions. Although EEG dipole source localization is widely used...

متن کامل

EEG Analysis on Skull Conductivity Perturbations Using Realistic Head Model

Measurement of electroencephalogram (EEG) requires accurate estimation of tissue conductivity. Among the head tissues, skull compartment has less conductivity due to compacta and spongiosa, which impacts on EEG measurement. Therefore, skull conductivity plays a vital role in head modeling, forward computation and source localization. In this study, we have investigated the effects of scalp pote...

متن کامل

A finite difference method with reciprocity used to incorporate anisotropy in electroencephalogram dipole source localization.

Many implementations of electroencephalogram (EEG) dipole source localization neglect the anisotropical conductivities inherent to brain tissues, such as the skull and white matter anisotropy. An examination of dipole localization errors is made in EEG source analysis, due to not incorporating the anisotropic properties of the conductivity of the skull and white matter. First, simulations were ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 37 8  شماره 

صفحات  -

تاریخ انتشار 2010