Meta-analysis of bleeding complications associated with cardiac rhythm device implantation.

نویسندگان

  • Michael L Bernard
  • Matthew Shotwell
  • Paul J Nietert
  • Michael R Gold
چکیده

BACKGROUND Many patients receiving cardiac rhythm devices have conditions requiring antiplatelet (AP) and/or anticoagulant (AC) therapy. Current guidelines recommend a heparin-bridging strategy (HBS) for anticoagulated patients with moderate/high risk for thrombosis. Several studies reported lower bleeding risk with continued oral anticoagulation rather than HBS. The best strategy for perioperative management of patients on AP therapy is less clear. The present study was designed as a meta-analysis of device implantation-associated bleeding complications using different AC/AP therapies. METHODS AND RESULTS PubMed and Cochrane Database searches identified articles based on design, outcomes, and available data. Device recipients were grouped as follows: no therapy, aspirin only, AC held, AC continued, dual AP, and HBS. The primary outcome was defined as a bleeding complication including hematoma, transfusion, or prolonged hospital stay. Thirteen articles were identified for analysis including 5978 patients. The combined incidence of bleeding complications was 274 of 5978 (4.6%), ranging from 2.2% (no therapy) to 14.6% (HBS). The estimated odds of bleeding were increased by 8.3 (95% CI, 5.5-12.9) times in the HBS group, 5.0 (95% CI, 3.0-8.3) for dual AP therapy, 1.7 (95% CI, 1.0-3.1) for AC held, 1.6 (95% CI, 0.9-2.6) for AC continued, and 1.5 (95% CI, 0.9-2.3) for aspirin only relative to the no therapy group. HBS significantly increased bleeding events compared with holding or continuing AC. Continuing AC did not increase bleeding events compared with no therapy. CONCLUSIONS Continuing AC appears safer than HBS for device implantation. Dual AP therapy but not continuing AC carries a significant risk of bleeding.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The safety and efficacy of antithrombotic therapy in patients undergoing cardiac rhythm device implantation: a meta-analysis.

AIMS The meta-analysis was to assess the safety and efficacy of periprocedural antithrombotic therapy and to evaluate the risk factors potentially associated with bleeding among patients undergoing cardiac implantable electronic devices implantations. METHODS AND RESULTS A systematic literature search of PubMed, EMBASE, and Cochrane Controlled Trials Register was performed. Anticoagulation an...

متن کامل

Dual antiplatelet therapy increases pocket hematoma complications in Chinese patients with pacemaker implantation

OBJECTIVE To assess the prevalence of the bleeding complications in pacemaker implanted patients receiving different antiplatelet regimens, and the influence of each regimen on hospital stays after device implantation. METHODS We prospectively enrolled 364 patients receiving the cardiac rhythm device implantations in Fuwai Hospital from July 2012 to December 2013. Bleeding complications inclu...

متن کامل

Bleeding complications during cardiac electronic device implantation in patients receiving antithrombotic therapy: is there any value of local tranexamic acid?

BACKGROUND The perioperative use of antithrombotic therapy is associated with increased bleeding risk after cardiac implantable electronic device (CIED) implantation. Topical application of tranexamic acid (TXA) is effective in reducing bleeding complications after various surgical operations. However, there is no information regarding local TXA application during CIED procedures. The purpose o...

متن کامل

Risk factors for lead complications in cardiac pacing: a population-based cohort study of 28,860 Danish patients.

BACKGROUND Lead complications are the main reason for reoperation after implantation of pacemakers (PM) or cardiac resynchronization therapy (CRT-P) devices. OBJECTIVE This study sought to describe the incidence of lead complications causing reoperation after device implantation and to identify risk factors for lead complications. METHODS A nationwide, population-based, historic cohort stud...

متن کامل

Incidence of and risk factors for infectious complications in patients with cardiac device implantation.

OBJECTIVES The use of cardiac implantable electronic device (CIED; pacemakers, implantable cardioverter-defibrillators [ICD], cardiac re-synchronized therapy [CRT]) implantation, one essential treatment for cardiac arrhythmias, is increasing. Infectious complications related to implants are the main reason for device removal and patient morbidity. We sought to identify the incidence of infectio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Arrhythmia and electrophysiology

دوره 5 3  شماره 

صفحات  -

تاریخ انتشار 2012