Modelling and simulation of low-density lipoprotein transport through multi-layered wall of an anatomically realistic carotid artery bifurcation.

نویسندگان

  • Saša Kenjereš
  • Alexander de Loor
چکیده

A high concentration of low-density lipoprotein (LDL) is recognized as one of the principal risk factors for development of atherosclerosis. This paper reports on modelling and simulations of the coupled mass (LDL concentration) and momentum transport through the arterial lumen and the multi-layered arterial wall of an anatomically realistic carotid bifurcation. The mathematical model includes equations for conservation of mass, momentum and concentration, which take into account a porous layer structure, the biological membranes and reactive source/sink terms in different layers of the arterial wall, as proposed in Yang & Vafai (2006). A four-layer wall model of an arterial wall with constant thickness is introduced and initially tested on a simple cylinder geometry where realistic layer properties are specified. Comparative assessment with previously published results demonstrated proper implementation of the mathematical model. Excellent agreement for the velocity and LDL concentration distributions in the arterial lumen and in the artery wall are obtained. Then, an anatomically realistic carotid artery bifurcation is studied. This is the main novelty of the presented research. We find a strong dependence between underlying blood flow pattern (and consequently the wall shear stress distributions) and the uptake of the LDL concentration in the artery wall. The radial dependency of interactions between the diffusion, convection and chemical reactions within the multi-layered artery wall is crucial for accurate predictions of the LDL concentration in the media. It is shown that a four-layer wall model produced qualitatively good agreement with the experimental results of Meyer et al. (1996) in predicting levels of LDL within the media of a rabbit aorta under identical transmural pressure conditions. Finally, it is demonstrated that the adopted model represents a good initial platform for future numerical investigations of the initial stage of atherosclerosis for patient-specific geometries.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of the fluid-structure interactions on low-density lipoprotein transport within a multi-layered arterial wall.

The effects of fluid-structure interactions (FSI) and pulsation on the transport of low-density lipoprotein (LDL) through an arterial wall are analyzed in this work. To this end, a comprehensive multi-layer model for both LDL transport as well as fluid-structure interaction (FSI) is introduced. The constructed model is analyzed and compared with the existing results in the limiting cases. Excel...

متن کامل

Hemodynamic conditions of patient-specific carotid bifurcation based on ultrasound imaging Corresponding author:

The purpose of this paper is to complement the characterization of patient-specific carotid artery bifurcation hemodynamics based on image data obtained by Doppler ultrasound imaging. A methodology for patient-specific 3D luminal surface reconstruction followed by structured hexahedral meshing of the volume and blood flow simulation is presented. Quantitative descriptors of the flow based on wa...

متن کامل

Carotid doppler ultrasound evaluation in patients with lichen planus

Background: Lichen planus is a chronic inflammatory disease associated with an increased risk of subclinical atherosclerosis and cardiovascular diseases. This study aimed to evaluate patients with lichen planus using carotid Doppler ultrasound parameters.Methods: Forty patients with lichen planus and 40 controls were included in this study. Common carotid...

متن کامل

Low Noise Measurement of Photocurrent for Continuous Glucose Monitoring - Low Noise Measurement System Enables Continuous Monitoring of Glucose in Subcutaneous Interstitial Fluid

The purpose of this work is mainly to manufacture several anatomical models in a polymeric material – polydimensiloxane (PDMS) to study the blood flow through a carotid artery bifurcation. Over the last few decades, research has been shown that the geometry of the carotid artery is closely related to the development of serious cardiovascular diseases. Hence, there is a considerable interest in ...

متن کامل

Effect of hypertension on low-density lipoprotein transport within a multi-layered arterial wall: modelling consistent with experiments

The influence of hypertension on low-density lipoproteins intake into the arterial wall is an important factor for understanding mechanisms of atherosclerosis. It has been experimentally observed that the increased pressure leads to the higher level of the LDL inside the wall. In this paper we attempt to construct a model of the LDL transport which reproduces quantitatively experimental outcome...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Royal Society, Interface

دوره 11 91  شماره 

صفحات  -

تاریخ انتشار 2014