PURPOSE ANSI/ADA has established standards for adequate radiopacity. This study was aimed to assess the changes in radiopacity of composite resins according to various tube-target distances and exposure times. MATERIALS AND METHODS Five 1-mm thick samples of Filtek P60 and Clearfil composite resins were prepared and exposed with six tube-target distance/exposure time setups (i.e., 40 cm, 0.2 seconds; 30 cm, 0.2 seconds; 30 cm, 0.16 seconds, 30 cm, 0.12 seconds; 15 cm, 0.2 seconds; 15 cm, 0.12 seconds) performing at 70 kVp and 7 mA along with a 12-step aluminum stepwedge (1 mm incremental steps) using a PSP digital sensor. Thereafter, the radiopacities measured with Digora for Windows software 2.5 were converted to absorbencies (i.e., A=-log (1-G/255)), where A is the absorbency and G is the measured gray scale). Furthermore, the linear regression model of aluminum thickness and absorbency was developed and used to convert the radiopacity of dental materials to the equivalent aluminum thickness. In addition, all calculations were compared with those obtained from a modified 3-step stepwedge (i.e., using data for the 2nd, 5th, and 8th steps). RESULTS The radiopacities of the composite resins differed significantly with various setups (p<0.001) and between the materials (p<0.001). The best predicted model was obtained for the 30 cm 0.2 seconds setup (R(2)=0.999). Data from the reduced modified stepwedge was remarkable and comparable with the 12-step stepwedge. CONCLUSION Within the limits of the present study, our findings support that various setups might influence the radiopacity of dental materials on digital radiographs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiopacity evaluation of contemporary resin composites by digitization of images

OBJECTIVE The aim of this study was to evaluate the radiopacity of different composite resins and compare the values to those of human enamel and dentine. MATERIALS AND METHODS Five specimens of each material with thicknesses of 2 mm were prepared and radiographed alongside aluminum step wedge and human enamel and dentin. Three occlusal radiographs for each material were taken and digitized u...

متن کامل

How does duration of curing affect the radiopacity of dental materials?

PURPOSE Clinicians commonly encounter cases in which it is difficult to determine whether adjacent radiopacities are normal or pathologic. The ideal radiopacity of composite resin is equal to or higher than that of the same thickness of aluminum. We aimed to investigate the possible effects of different curing times on the post-24-hour radiopacity of composite resins on digital radiographs. M...

متن کامل

Radiopacity of Restorative Materials Using Digital Images

The radiopacity of esthetic restorative materials has been established as an important requirement, improving the radiographic diagnosis. The aim of this study was to evaluate the radiopacity of six restorative materials using a direct digital image system, comparing them to the dental tissues (enamel-dentin), expressed as equivalent thickness of aluminum (millimeters of aluminum). Five specime...

متن کامل

Radiopacity of glass-ionomer/composite resin hybrid materials.

This study visually compared the radiopacity of seven restorative materials (3 resin-modified glass-ionomer cements, 3 polyacid-modified composite resins, and 1 conventional glass-ionomer cement) to a sound tooth structure sample, and an aluminium stepwedge. All hybrid materials were more radiopaque, except for one resin-modified glass-ionomer cement, than both the tooth structure and conventio...

متن کامل

Comparison of radiopacity of different composite resins

BACKGROUND The radiopacity of composite resins has been considered as an important requirement, improving the radiographic diagnosis. AIM The present study aimed to compare the radiopacity of eight different composite materials using an aluminum step wedge. MATERIALS AND METHODS Eight different composite resins were used in this study. The samples were prepared using a stainless steel mold ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 42  شماره 

صفحات  -

تاریخ انتشار 2012