Is an Impacted Morselized Graft in a Cage an Alternative for Reconstructing Segmental Diaphyseal Defects?
نویسندگان
چکیده
Large diaphyseal bone defects often are reconstructed with large structural allografts but these are prone to major complications. We therefore asked whether impacted morselized bone graft could be an alternative for a massive structural graft in reconstructing large diaphyseal bone defects. Defects in the femora of goats were reconstructed using a cage filled with firmly impacted morselized allograft or with a structural cortical autograft (n = 6 in both groups). All reconstructions were stabilized with an intramedullary nail. The goats were allowed full weightbearing. In all reconstructions, the grafts united radiographically. Mechanical torsion strength of the femur with the cage and structural cortical graft reconstructions were 66.6% and 60.3%, respectively, as compared with the contralateral femurs after 6 months. Histologically, the impacted morselized graft was replaced completely by new viable bone. In the structural graft group, a mixture of new and necrotic bone was present. Incorporation of the impacted graft into new viable bone suggests this type of reconstruction may be safer than reconstruction with a structural graft in which creeping substitution results in a mixture of viable and necrotic bone that can fracture. The data suggest that a cage filled with a loaded morselized graft could be an alternative for the massive cortical graft in reconstruction of large diaphyseal defects in an animal model.
منابع مشابه
Comparative effectiveness of two different interbody fusion methods for transforaminal lumbar interbody fusion: cage versus morselized impacted bone grafts
BACKGROUND The use of an interbody fusion device (cage) to assist fusion and increase intervertebral stability is widely supported. We applied the morselized impacted bone graft method without using a cage in a single level interbody fusion with encouraging medium-term clinical results. The purpose of this paper is to compare the clinical and radiological results of local bone grafts with a cag...
متن کاملDevelopment of a Three-Dimensional (3D) Printed Biodegradable Cage to Convert Morselized Corticocancellous Bone Chips into a Structured Cortical Bone Graft
This study aimed to develop a new biodegradable polymeric cage to convert corticocancellous bone chips into a structured strut graft for treating segmental bone defects. A total of 24 adult New Zealand white rabbits underwent a left femoral segmental bone defect creation. Twelve rabbits in group A underwent three-dimensional (3D) printed cage insertion, corticocancellous chips implantation, and...
متن کاملRinsing of allograft bone does not improve implant fixation
BACKGROUND AND PURPOSE Impacted morselized allograft bone is a well-established method for reconstructing bone defects at revision surgery. However, the incorporation of bone graft is not always complete, and a substantial volume of fibrous tissue has been found around grafted implants. We hypothesized that rinsing the bone graft may improve graft incorporation by removing the majority of immun...
متن کاملBone healing of severe acetabular defects after revision arthroplasty
BACKGROUND AND PURPOSE Healing of acetabular bone grafts may be difficult to assess in conventional radiographs. We used PET to analyze healing of morselized bone allografts, impacted in large osteolytic acetabular defects at revision arthroplasty. PATIENTS AND METHODS 7 cases had a cup revision because of loosening, with repair of a segmental defect using a perforated, wide and thin plate. T...
متن کاملThe use of morselized allografts without impaction and cemented cage support in acetabular revision surgery: a 4- to 9-year follow-up
BACKGROUND Acetabular revision arthroplasty with major bone loss is one of the most difficult operations in orthopedic surgery. The goal of the study was to evaluate midterm clinical results of the use of morselized allografts with cemented cage support in revision total hip replacement. METHODS We identified 28 patients (29 hips) at an average follow-up of 73 months. Harris Hip Scores (HHS) ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical Orthopaedics and Related Research
دوره 467 شماره
صفحات -
تاریخ انتشار 2009