A micro-computed tomography evaluation of long-oval canal preparation using reciprocating or rotary systems.

نویسندگان

  • S Busquim
  • R S Cunha
  • L Freire
  • G Gavini
  • M E Machado
  • M Santos
چکیده

AIM To evaluate, using micro-computed tomography, the preparation of long-oval root canals using a single reciprocating system versus a multiple-file rotary system. METHODOLOGY Distal canals of thirty mandibular molars were selected and randomly assigned to one of two instrument groups (n = 15): Reciproc 40 (VDW, Munich, Germany) or BioRaCe system (FKG Dentaire, La Chaux-de-Fonds, Switzerland). The teeth were scanned before and after preparation of the canal by a SkyScan 1172 micro-computed tomography scanner at 11-μm resolution. Morphometric variations were measured by volume increases and by the remaining untreated canal surface area in the entire canal and as well as in each third of the canal. Data were compared using the Mann-Whitney test. RESULTS The Reciproc system left significantly more areas untouched (P < 0.001) in the cervical and middle thirds (18.14% and 21.82%) as compared to BioRaCe (8.14% and 11.35%). The Reciproc system had the greatest increase in volume of both the entire canal and the apical third (P < 0.5). CONCLUSIONS Neither technique was able to completely prepare the outline of long-oval canals. The Reciproc system removed more tooth structure. The BioRaCe left fewer untouched dentine walls in the more coronal thirds of the canal, whilst Reciproc left fewer in the apical third.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Micro-computed tomography evaluation of the preparation of long oval root canals in mandibular molars with the self-adjusting file.

INTRODUCTION The aim of this study was to assess the shaping potential of a novel nickel-titanium instrument, the self-adjusting file (SAF), in long oval root canals in distal roots in mandibular molars. METHODS Twenty mandibular molars with long oval distal root canals were selected and scanned preoperatively and postoperatively by using micro-computed tomography at an original resolution of...

متن کامل

Stages of Retreatment Procedure

re-preparation with rotary or reciprocating files and passive ultrasonic irrigation (PUI). Twenty maxillary molars were prepared using ProTaper instruments up to F1. The teeth were filled with AH Plus and ProTaper gutta-percha points using the single-cone technique. Thereafter, the specimens were scanned using a micro-computed tomography system (Micro-CT #1). Then, the root canal filling was re...

متن کامل

Micro-computed tomography evaluation of the preparation of long oval root canals in mandibular molars with the self-adjusting file

INTRODUCTION: The aim of this study was to assess the shaping potential of a novel nickeltitanium instrument, the self-adjusting file (SAF), in long oval root canals in distal roots in mandibular molars. METHODS: Twenty mandibular molars with long oval distal root canals were selected and scanned preoperatively and postoperatively by using micro-computed tomography at an original resolution of ...

متن کامل

Flat-oval root canal preparation with self-adjusting file instrument: a micro-computed tomography study.

INTRODUCTION The aim of this study was to evaluate the root canal preparation in flat-oval canals treated with either rotary or self-adjusting file (SAF) by using micro-tomography analysis. METHODS Forty mandibular incisors were scanned before and after root canal instrumentation with rotary instruments (n = 20) or SAF (n = 20). Changes in canal volume, surface area, and cross-sectional geome...

متن کامل

Reciprocating root canal technique induces greater debris accumulation than a continuous rotary technique as assessed by 3-dimensional micro-computed tomography.

INTRODUCTION The ability of single-file, reciprocating instruments to remove inorganic debris is uncertain. By using micro-computed tomography (microCT), this study compared the 3-dimensional distribution, quantity, and density of remaining inorganic debris in the mesial root of mandibular molars after instrumentation. A single reciprocating file was compared with a multifile rotary instrumenta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International endodontic journal

دوره 48 10  شماره 

صفحات  -

تاریخ انتشار 2015