16 a - [ 1251 ] - $ - EstradiolComparedwith [ 3 H ] - f 3 - Estradiolas the Tracer in EstradiotReceptorAssays Juan
نویسندگان
چکیده
We assessed the potential usefulness of 16a-[’25l]/3-estradiol in estradiol receptor assays as compared with a long-used [3H] -f3-estradiol dextran-coated charcoal method, measuring 472 consecutive human breast-cancer cytosols by both procedures. Six different preparations of 16 a-[125l]--estradiol were used. Nonspecific binding in five batches was similar and comparable to [3H]-/3-estradiol. Although the sixth batch had increased nonspecific binding, this did not affect results. Dissociation constants were virtually identical (r = 0.94). Results were concordant for 98.5% of cytosols: 161 were negative and 304 positive by both methods and seven were positive by one method, negative by the other. Four were positive with the 1251 procedure and undetectable with [3H]-f3-estradiol. Three were measurable by both methods, but were above the cut-off value in one and below it in the other. We find 16a-[’25l]-fl-estradiol to be an adequate substitute for [3H] -f3-estradiol in estradiol receptor assays.
منابع مشابه
A Direct Radioimmunoassayof Serum Cortisolwith In-House1251... Tracer and PreconjugatedDoubleAntibody
We describe a radioimmunoassay of serum cortisol in which 1251-tracerand preconjugated double antibody are used. This simpler method involves direct serum assay, and the majority of reagents are prepared in-house. Within-assay precision (coefficient of variation) of assay for Ortho Diognostic AlA Cortisol I and II was 3.2% (mean = 131 ig/L, n = 10)and2.2% (mean = 405 tg/L, n = 10), respectively...
متن کاملPreparation and quality control of radiolabeled streptokinase for Thrombosis imaging
Background: In order to diagnose the site of thrombi, radiolabeled streptokinase can be prepared. The radiolabeled compound can be used in imaging of thrombi in many cardiovascular diseases. Materials and Methods: Streptokinase was successively labeled with [67Ga]-gallium chloride using cyclic DTPA-dianhydride. The conjugation with DTPA was optimized for concentration, time and temperature foll...
متن کاملComparisonof Three Radioligands,Selenium-75, Iodine-125, and Tritium,in the Radioimmunoassayof Methotrexate
Radioimmunoassays for methotrexate are described, involving use of a rabbit antiserum to a conjugate of the drug and bovine serum albumin and the drug labeled with tritium, selenium-75, or iodine-125. Of the two gamma emitters, the 75Se-labeled drug was prepared by the Radiochemical Centre, Amersham, England and the 1251-labeled drug in the laboratory, by the Chloramine T iodination technique. ...
متن کاملThe Effect of Different Stabilizers on Stability of Horseradish Peroxidase- Bovine Serum Albumin-Aflatoxin B1, a Conjugated Tracer for Detection of Aflatoxin B1 in Immunoassay-Based Methods
Aflatoxins are a group of fungal toxic metabolites, which are contaminated certain food commodities. ELISA is one of the sensitive methods for detection of aflatoxins. Preparation and stabilizing of a proper conjugated tracer for detection of aflatoxins is probably the main step for designing an ELISA method. In current study, different stabilizers were applied to stabilize a newly prepared con...
متن کاملPreparation and Biodistribution of [67Ga]-labeled- oxytocin for SPECT purposes
Background: Oxytocin (OT) is a paracrine hormone with various biological activities and many sex organs in both sexes, as well as many tumor cells have shown to have related receptors. In this study the development of a receptor imaging tracer for possible tumor imaging has been described. Materials and Methods: OT was successively labeled with [67Ga]-gallium chloride after conjugation with fre...
متن کامل