Correlation between fractional exhaled nitric oxide and sputum eosinophilia in exacerbations of COPD

نویسندگان

  • Jie Gao
  • Min Zhang
  • Liqin Zhou
  • Xing Yang
  • Haigui Wu
  • Jianfang Zhang
  • Feng Wu
چکیده

INTRODUCTION Measurements of eosinophils in induced sputum and fractional exhaled nitric oxide (FeNO) are noninvasive biomarkers for assessing airway inflammation phenotypes in chronic obstructive pulmonary disease (COPD). Nevertheless, the clinical application of the correlation between FeNO levels and sputum eosinophilia is controversial. The study aimed to investigate the correlation and predictive relationship between FeNO levels and sputum eosinophils in patients with COPD exacerbation. It also examined the relationship between FeNO levels and blood eosinophil percentage. METHODS A total of 163 patients with COPD exacerbation were included in the cross-sectional study. All patients underwent the following on the same day: FeNO test, spirometry, bronchodilator reversibility test, induced sputum, and routine blood test. They were classified as eosinophilic group or noneosinophilic group based on sputum eosinophilic percentage (≥2.5%)/FeNO levels (≥32 parts per billion [ppb]). RESULTS FeNO levels and blood eosinophilic percentage were higher in patients with sputum eosinophilia (n=62) compared to those without (31.35 ppb versus 21.43 ppb, P=0.015; 2.71% versus 0.98%, P<0.0001, respectively). Sputum eosinophilic percentage was higher with raised FeNO (n=34) compared to those with FeNO <32 ppb (5.12% versus 3.12%, P=0.007). Eosinophils in induced sputum correlated with both FeNO levels (ρ=0.221, P=0.005) and blood eosinophilic percentage (ρ=0.399, P<0.001). There was no relationship between FeNO and blood eosinophilic percentage. Blood eosinophilic percentage was predictive of sputum eosinophilia (95% confidence interval [CI] =0.65-0.81, P<0.001) at a cutoff point of 0.65% (sensitivity =73%, specificity =61.3%). FeNO levels were predictive of sputum eosinophilia (95% CI =0.53-3,071, P=0.012) at a cutoff point of 17.5 ppb (sensitivity =65.1%, specificity =56.4%). CONCLUSION The clinical relevance of this study provides evidence that inflammatory biomarkers, including sputum eosinophilic percentage, FeNO level, and blood eosinophilic percentage, can be used to positively diagnose eosinophilic COPD. The FeNO level and blood eosinophilic counts/percentage, which determine an optimal cutoff for sputum eosinophilia, need more studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Infections and airway inflammation in chronic obstructive pulmonary disease severe exacerbations.

RATIONALE Severe exacerbations of chronic obstructive pulmonary disease (COPD) are major causes of health care costs mostly related to hospitalization. The role of infections in COPD exacerbations is controversial. OBJECTIVES We investigated whether COPD exacerbations requiring hospitalization are associated with viral and/or bacterial infection and evaluated relationships among infection, ex...

متن کامل

Clinical aspects of exhaled nitric oxide.

There has been intense research into the role nitric oxide (NO) plays in physiological and pathological mechanisms and its clinical significance in respiratory medicine. Elevated levels of exhaled levels of exhaled NO in asthma and other inflammatory lung diseases lead to many studies examining NO as potential markers of airway inflammation, enabling repeated noninvasive and standardized monito...

متن کامل

Yes to NO: the first studies on exhaled nitric oxide-driven asthma treatment.

R ecently, the first long-term studies examining the use of fractional exhaled nitric oxide (FeNO) to titrate steroid treatment in asthma were published [1, 2]. Treatment decisions in asthma have always been made on the basis of symptoms, with or without taking peak flow into account. It is well established that, within an asthma population, both symptoms and airway obstruction correlate poorly...

متن کامل

Markers of nitric oxide metabolism in sputum and exhaled air are not increased in chronic obstructive pulmonary disease.

BACKGROUND Nitric oxide (NO) is involved in inflammation and host defence of the lung. It has been found in increased concentrations in the airways in asthmatic subjects but its levels in patients with chronic obstructive pulmonary disease (COPD) have not been investigated. A study was undertaken to determine whether markers of NO metabolism (NO in exhaled air, iNOS expression in sputum cells, ...

متن کامل

Sputum eosinophils and exhaled nitric oxide during late asthmatic reaction in patients with western red cedar asthma.

Examination of sputum for eosinophils and measurement of exhaled nitric oxide have been proposed as noninvasive methods of assessing airway inflammation in asthma. The use of these tests in the evaluation of patients with occupational asthma has not been reported. This study investigated the changes in sputum eosinophils and exhaled NO before and at intervals after inhalation challenge with pli...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017