Ultrasonic Time Reversal Mirrors

نویسندگان

  • Mathias Fink
  • Gabriel Montaldo
  • Mickael Tanter
چکیده

For more than ten years, time reversal techniques have been developed in many different fields of applications including detection of defects in solids, underwater acoustics, room acoustics and also ultrasound medical imaging and therapy. The essential property that makes time reversed acoustics possible is that the underlying physical process of wave propagation would be unchanged if time were reversed. In a non dissipative medium, the equations governing the waves guarantee that for every burst of sound that diverges from a source there exists in theory a set of waves that would precisely retrace the path of the sound back to the source. If the source is pointlike, this allows focusing back on the source whatever the medium complexity. For this reason, time reversal represents a very powerful adaptive focusing technique for comp lex media The generation of this reconverging wave can be achieved by using Time Reversal Mirrors (TRM). It is made of arrays of ultrasonic reversible piezoelectric transducers that can record the wavefield coming from the sources and send back its time-reversed version in the medium. It relies on the use of fully programmable multi-channel electronics. In this paper we present some applications of iterative time reversal mirrors to target detection in medical applications. THE TIME REVERSAL MIRROR IN PULSE ECHO MODE One of the most promising areas for the application of TRMs is pulse-echo detection. In this domain, one is interested in detection, imaging and sometimes destruction of passive reflecting targets. A set of transducers first sends a short impulse and then detects the various echoes from the targets. One looks for calcifications, kidney or gallbladder stones, or tumors. As the acoustic detection quality depends on the availability of the sharpest possible ultrasonic beams to scan the medium of interest, the presence of an aberrating medium between the targets and the transducers can drastically change both the beam profiles and the detection capability. In medical imaging, a fat layer of varying thickness, bone tissues, or some muscular tissues may greatly degrade focusing. For such applications, a TRM array can be controlled according to a three step sequence. One part of the array generates a brief pulse to illuminate the region of interest through any aberrating medium. If the region contains a point reflector, the reflected wavefront is selected by means of a temporal window and then the acquired information is time-reversed and reemitted. The reemitted wavefront refocuses on the target through the medium. It compensates also for unknown deformation of the mirror array. Although this selffocusing technique is highly effective, it requires the presence of a reflecting target in the medium [1]. In media containing several targets, the problem is more complicated and iterations of the TR operation may be used to select one target. Indeed, if the medium contains two targets of different reflectivities, the time-reversal of the echoes reflected from these targets generates two wavefronts focused on each target. The mirror produces the real acoustic images of the two reflectors on themselves. The highest amplitude wavefront illuminates the most reflective target, while the weakest wavefront illuminates the second target. In this case, the time-reversal process can be iterated. After the first time-reversed illumination, the weakest target is illuminated more weakly and reflects a fainter wavefront than the one coming from the strongest target. After some iterations, the process converges and produces a wavefront focused on the most reflective target. It converges if the target separation is sufficient to avoid the illumination of one target by the real acoustic image of the other one [2]. Application to lithotripsy The method of choice to treat kidney and gall stones involves the use of large amplitude acoustic shock waves that are generated extracorporeally and focused onto a stone within the body. Lithotripters typically have a high focusing gain so that pressures are high at the stone but substantially lower in the surrounding tissue. The alignment of stone in the patient with the lithotripter focus is accomplished with fluoroscopy or ultrasonic imaging. Focusing is achieved geometrically, i.e., with ellipsoidal reflectors, concave focusing arrays of piezoelectric transducers, or acoustic lenses. Shock waves have amplitudes at the focus on the order of 1.000 bar and a duration of a few microseconds. They are typically fired at a 1 s pulse repetition rate [3,4]. The main problem to overcome in the field of lithotripsy is related to stone motion due to breathing. Indeed, the lateral dimension of the shock wave in current lithotripsy devices is less than 5 mm and the amplitude of the stone displacement can reach up to 20 mm from the initial position. Hence, in classical focusing technique, shock waves often miss the stone and subject neighboring tissues to unnecessary shocks that may cause local bleeding. Different approaches have been investigated to overcome these limitations. Most of them are based on a trigger of the high power pulses when the stone goes through the focus of the shock wave generator. These approaches may reduce the number of shots needed to disintegrate the stone but increase considerably the time of treatment. The use of 2D arrays of piezoelectric transducers has opened the possibility of electronic steering and focusing the beam in biological tissues and a time-reversal piezoelectric generator has been developed [5] to move electronically the focus and track the stone during a lithotripsy treatment. The goal is to locate and focus on a given reflecting target among others, for example, a stone in its surroundings: others stones and organ walls. Moreover, the stone is not a point like reflector but has dimensions up to ten times the wavelength. In the basic procedure that has been developed, the region of interest is first insonified by the transducer array. The reflected field is sensed on the whole array, time-reversed and retransmitted. As the process is iterated, the ultrasonic beam selects the target with the highest reflectivity. If the target is spatially extended, the process converges on one spot, whose dimensions depend only on geometry of the time-reversal mirror and the wavelength. High amplification during the last iteration can be used to produce a shock wave for stone destruction. However, two problems limit this technique. For human applications, it is necessary to use very short high power signals (bipolar and unipolar pulses) to prevent damages caused in the organs by cavitational gas bubbles, while the iterated pulses have long duration. Besides, a complete time-reversal electronic is expensive and the number of time-reversal channels must be limited. To solve these problems, another procedure has been developed. In the first step, only a subgroup of the array is used in a time-reversed mode. This step is conducted with low power ultrasound in order to remain in linear acoustics. After some iterations, a low power ultrasonic beam, generated by the array subgroup, is focused on the stone. The last set of received signals is used to deduce a time of flight profile on the subgroup. This time of flight profile is then interpolated to the whole array. The final step consists in the generation, by the whole array, of very short high power signals with the correct delays. Different time reversal mirrors have been designed for lithotripsy. They use bidimensional transducer arrays working at a central frequency of 360 kHz, made of 121 prefocused piezoelectric transducer elements arranged on a spherical cup of 190 mm radius of curvature Multiple target detection Iterative time reversal technique is well adapted to focus on the target of higher reflectivity. However, in many cases it is also interesting to learn how to focus on the other reflectors. In order to achieve selective detection and focusing on each reflector inside an unknown multitarget medium, a matrix formalism approach, that extended time reversal analysis, was developed by Prada et al [6,7,8]. This method is derived from the theoretical analysis of iterative TRM and consists at the construction of the invariant of the time reversal process. This analysis consists at determining the possible transmitted waveforms that are invariant under the time reversal process. For these waveforms an iteration of the time reversal operation gives stationary results. Such waveforms can be determined through the calculation of the eigenvectors of the so called time reversal operator. Indeed, the echoes of a single target are an eigenvector of the time reversal operator K*K, where K=K(? ) represents the interelement response matrix. Using this basic idea that each target is associated to an eigenvector of the time reversal operator, it is possible to record the whole time reversal operator and compute its eigenvectors decomposition. Thanks to this numerical eigenvector decomposition, a selective focusing on each target can be achieved. Using this technique, known as the DORT method, Chambers recently shown that the spectrum of the time reversal operator can be complex and very informative [9]. Nevertheless, the D.O.R.T method suffers several limitations as it requires the measurement of the NxN inter-element impulse responses and the computation of the eigenvector decomposition is quite time consuming and does not allow real time imaging. A new real time technique has been recently proposed by G.Montaldo et al [10] for multitarget selective focusing that does not require the experimental acquisition of the time reversal operator. Actually, this technique achieves the operator decomposition simply by using a particular sequence of iterative wave illuminations instead of computational power. The general idea of this new approach is first to use the time reversal iterative process in order to estimate the signals focusing on the brightest target. These signals are then used to derive a cancellation filter allowing canceling target’s echoes during the selection of the next brightest spot by iterative time reversal. This process can be extended to following multiple target detection using the cancellation filter that cleans up the targets already detected. FIGURE 1. The iterative process. a) Echoes from the 3 scatterers after a plane wave emission. b) Detection of the strongest scatterer by iterative time reversal. c) Eigenpulse of the first scatterer. d) Echoes from the two scatterers after filtering the first one. e) Detection of the second scatterer by time reversal and filtering . f) Eigenvector of the second scatterer. g) Signal of the 3rd scatterer after filtering the first and second. h) Detection of the 3rd scatterer by time reversal and filtering. i) Eigenpulse of the

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving the air coupling of bulk piezoelectric transducers with wedges of power-law profiles: a numerical study.

An air-coupled ultrasonic transducer is created by bonding a bulk piezoelectric element onto the surface of a thick plate with a wedge of power-law profile. The wedge is used to improve the ultrasonic radiation efficiency. The power-law profile provides a smooth, impedance-matching transition for the mechanical energy to be transferred from the thick plate to the air, through the large-amplitud...

متن کامل

Ultrasonic Focusing and Steering Through Skull: Towards Brain Imaging

me time reversal process is applied to focus pulsed ultrasonic waves through the human skull bone. The aim is here whether to treat brain tumors, which are difficult to reach with classical surgery means, or to achieve ultrasonic imaging of the brain. Such medical applications require precise control of the size and location of the ultrasonic focal beam. But, the severe ultrasonic attenuation i...

متن کامل

Time-reversal acoustics in biomedical engineering.

Time reversal is a very powerful method for focusing through complex and heterogeneous media and shows very promising results in biomedical applications. In this paper, we review some of the main applications investigated during the past decade. An iterative implementation of the time-reversal process allows tracking gallstones in real time during lithotripsy treatments. In this application dom...

متن کامل

Far Field Modeling of Electromagnetic Time Reversal and Application to Selective Focusing on Small Scatterers

A time harmonic far field model for closed electromagnetic time reversal mirrors is proposed. Then, a limit model corresponding to small perfectly conducting scatterers is derived. This asymptotic model is used to prove the selective focusing properties of the time reversal operator. In particular, a mathematical justification of the DORT method (Decomposition of the Time Reversal Operator meth...

متن کامل

Demonstration of Super-Resolution and Super-Stacking Properties of Time Reversal Mirrors in Locating Seismic Sources

We demonstrate with synthetic seismic data the superresolution and super-stacking properties of time reversal mirrors (TRM). Tests on synthetic data show that TRM has the potential of exceeding the Rayleigh resolution limit by a factor of more than 9. This property is accompanied by the fact that TRM has a significant resilience to strong noise. Computer tests validate these properties by accur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004