Mechanical assessment of an anisotropic conductive adhesive joint of a direct access sensor on a flexible substrate for a swallowable capsule application

نویسندگان

  • P. Jesudoss
  • Alan Mathewson
  • W. M. D. Wright
  • F. Stam
چکیده

0026-2714/$ see front matter 2012 Elsevier Ltd. A http://dx.doi.org/10.1016/j.microrel.2012.09.014 ⇑ Corresponding author. Tel.: +353 214904142. E-mail addresses: [email protected] (P. tyndall.ie (A. Mathewson), [email protected] (W.M.D 1 Tel.: +353 214904142. 2 Tel.: +353 214902213. Sensor interconnection achieved with Flip Chip (FC) technology and most particularly with Anisotropic Conductive Adhesive (ACA) is a very attractive technique, in achieving a Direct Access Sensor (DAS), in a swallowable diagnostic sensing capsule. This paper describes the work carried out to mechanically characterise the ACA joints when they are inserted in the capsule to determine the smallest capsule diameter that could be used without imparting excessive stress on the interconnect in the DAS integration process for a specific substrate and chip design. Three point inward bending was used to study the effect of the mechanical loading on the joints during the insertion process. The results showed that the insertion force linearly increased and leveled off at a, low friction, constant value. The spring constant of the linear region in a 23 mm was 0.2729 N/mm and increased to 1.5 N/mm for the 15 mm diameter hole. It showed that the spring constant decreased linearly as the diameter increased, signifying that for the same distance, less force will be required in a larger diameter hole than in the small diameter holes. During insertion the stress in the assembly, was higher towards the centre of the chip and the window than at the edge of the chip and the ACA fillet. This was characterised by it exhibiting lower voltage values measured in the partial daisy chains that were close to the window rather than the ones that were situated away from the window. The insertion test suggested that the 23 mm diameter hole would be the smallest suitable hole for insertion of this assembly. Failure analysis revealed that the depression and the wide crack close to the window imply that the stress was high in this region. The cross sectional analysis showed that failure occurred within silicon/silicon chip pad and that the ACA contacts form a strong joint and was able to withstand the insertion force required to secure the ACA sensor in place before encapsulation. 2012 Elsevier Ltd. All rights reserved.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Identification of Dynamic Damping Properties of a Flexible Structural Adhesive

In this paper dynamic damping properties of a nominated flexible structural adhesive have been identified using an extended-direct modal based joint identification method. It has been revealed that damping characteristics of adhesive are correlated to both frequency and mode shape. Young’s and shear moduli increase with frequency but damping on the other hand, decrease. The results showed that ...

متن کامل

Study of anisotropic conductive adhesive joint behavior under 3-point bending

Flip chip interconnections using anisotropic conductive film (ACF) are now a very attractive technique for electronic packaging assembly. Although ACF is environmentally friendly, many factors may influence the reliability of the final ACF joint. External mechanical loading is one of these factors. Finite element analysis (FEA) was carried out to understand the effect of mechanical loading on t...

متن کامل

Flip chip microassembly of a silicon triaxial force sensor on flexible substrates

Miniaturization of microelectromechanical systems (MEMS) based devices can be achieved by flip chip assembly directly onto a flexible circuit substrate. The main goal of this work was the selection of a suitable bonding material and process to enable scaling down of MEMS sensorized devices for biomedical applications. Finally, the heat bondable anisotropic conductive film 5552R (3M) allowed mec...

متن کامل

Analytical Solution of Stress Field in Adhesively Bonded Composite Single-Lap Joints Under Mechanical Loadings

In this paper, considering an adhesively bonded composite single-lap joint, a novel approach is presented to predict the peel and shear stress distributions of the adhesive layer for an ASTM standard test sample. In current method, the equilibrium equations are derived using the energy method and based on the Timoshenko’s beam theory. Two solution procedures then are discussed, one of which rep...

متن کامل

Scalable Microfabrication Procedures for Adhesive-Integrated Flexible and Stretchable Electronic Sensors

New classes of ultrathin flexible and stretchable devices have changed the way modern electronics are designed to interact with their target systems. Though more and more novel technologies surface and steer the way we think about future electronics, there exists an unmet need in regards to optimizing the fabrication procedures for these devices so that large-scale industrial translation is rea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Microelectronics Reliability

دوره 53  شماره 

صفحات  -

تاریخ انتشار 2013