Accuracy in tooth positioning with a fully customized lingual orthodontic appliance.
نویسندگان
چکیده
INTRODUCTION To understand orthodontic tooth movement, a method of quantification of tooth position discrepancies in 3 dimensions is needed. Brackets and wires now can be fabricated by CAD/CAM technology on a setup made at the beginning of treatment, so that treatment should produce a reasonably precise duplicate of the setup. The extent of discrepancies between the planned and actual tooth movements can be quantified by registration of the setup and final models. The goal of this study was to evaluate the accuracy of a CAD/CAM lingual orthodontic technique. METHODS Dental casts of 94 consecutive patients from 1 practice, representing a broad range of orthodontic problems, were scanned to create digital models, and then the setup and final models for each patient were registered individually for the maxillary and mandibular dental arches. Individual tooth discrepancies between the setup and actual outcome were computed and expressed in terms of a six-degrees-of-freedom rectangular coordinate system. RESULTS Discrepancies in position and rotation between the setup and outcome were small for all teeth (generally less than 1 mm and 4°) except for the second molars, where some larger discrepancies were observed. Faciolingual expansion in the posterior teeth was greater in the setup than in the final models, especially at the second molars. Linear mixed models showed that age, type of tooth, jaw, initial crowding, time in slot-filling wire, use of elastics, days in treatment, interproximal reduction, and rebonding, were all influences on the final differences, but, for most of these factors, the influence was small, explaining only a small amount of the discrepancy between the planned and the actual outcomes. CONCLUSION These fully customized lingual orthodontic appliances were accurate in achieving the goals planned at the initial setup, except for the full amount of planned expansion and the inclination at the second molars. This methodology is the first step toward understanding and measuring tooth movement in 3 dimensions.
منابع مشابه
Adult Patients
Current advances in orthodontics have broadened the possibilities of invisible orthodontic appliances offered to adult patients. For some patients, aesthetic considerations during treatment are as important as other factors, such as comfort, pain, cost, or length of treatment . Traditional labial appliances (Buccal) remain the main orthodontic appliance used. The introduction of the lingual app...
متن کاملSelf-ligating fully customized lingual appliance and chair-time reduction: a typodont study followed by a randomized clinical trial.
In this study, we tested the hypothesis that self-ligation can reduce the chair time necessary for inserting and removing the archwire in a fully customized, multi-bracket, orthodontic, lingual appliance. A permuted-block, randomized trial design was employed to treat seven patients, each with Incognito(®) lingual appliances and Harmony(®) self-ligating lingual appliances. Three operators (a th...
متن کاملDigital design and manufacturing of the Lingualcare bracket system.
duced in the early 1970s, used conventional labial brackets that were modified by the clinician and bonded directly to the lingual surfaces. Brackets designed specifically for lingual usage1-4 were initially prone to technical problems that made them difficult to use in everyday practice. The development of indirect bonding permitted more precise lingual bracket positioning and reduced the chai...
متن کاملA concept to transfer a therapeutic splint position into permanent occlusion with a customized lingual appliance
INTRODUCTION The role of occlusion concerning temporomandibular disorder is still unclear but seems to be the only component of the stomathognathic system dentists are able to change morphologically. The aim of the paper is to describe the orthodontist's approach for transferring and maintaining a therapeutic splint position into permanent occlusion using a fully customized lingual appliance. ...
متن کاملLingual orthodontic treatment duration: performance of two different completely customized multi-bracket appliances (Incognito and WIN) in groups with different treatment complexities
INTRODUCTION The occurrence of side-effects of fixed orthodontic therapy, such as white-spot lesions and root resorption, are known to be significantly more frequent with increasing duration of treatment. Multi-bracket treatment should be as short as possible, in order to minimize the risks of collateral damage to teeth. The aim of this non-randomized clinical trial was to compare treatment dur...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics
دوره 140 3 شماره
صفحات -
تاریخ انتشار 2011