Untargeted Intramuscular EMG
نویسندگان
چکیده
Center for Sensory-Motor Interaction, Department of Health Science and Technology, Aalborg 6 University, Aalborg, Denmark. 7 Institute of Biomedical Engineering, Department of Electrical and Computer Engineering, University of 8 New Brunswick, Fredericton, NB, Canada. 9 10 • Ernest N. Kamavuako performed the design and execution of experiments, performed the analysis, and 11 drafted the manuscript. 12 • Kevin B. Englehart and Erik J. Scheme contributed to the analysis, and preparation and critical revision of 13 the manuscript. 14 • All authors read and approved the final manuscript. 15 16 17 *Corresponding Author: 18 Ernest N. Kamavuako, Center for Sensory-Motor Interaction (SMI), Department of HST, Aalborg 19 University, Fredrik Bajers Vej 7 D3, DK-9220 Aalborg, Denmark, tel: +45 99402461. E-mail: 20 [email protected] 21 22 23 Articles in PresS. J Neurophysiol (March 20, 2013). doi:10.1152/jn.00086.2013
منابع مشابه
Wrist torque estimation during simultaneous and continuously changing movements: surface vs. untargeted intramuscular EMG.
In this paper, the predictive capability of surface and untargeted intramuscular electromyography (EMG) was compared with respect to wrist-joint torque to quantify which type of measurement better represents joint torque during multiple degrees-of-freedom (DoF) movements for possible application in prosthetic control. Ten able-bodied subjects participated in the study. Surface and intramuscular...
متن کاملComparative Analysis of Wavelet-based Feature Extraction for Intramuscular EMG Signal Decomposition
Background: Electromyographic (EMG) signal decomposition is the process by which an EMG signal is decomposed into its constituent motor unit potential trains (MUPTs). A major step in EMG decomposition is feature extraction in which each detected motor unit potential (MUP) is represented by a feature vector. As with any other pattern recognition system, feature extraction has a significant impac...
متن کاملElectromyographic measures of muscle activation and changes in muscle architecture of human elbow flexors during fatiguing contractions.
The study compared changes in intramuscular and surface recordings of EMG amplitude with ultrasound measures of muscle architecture of the elbow flexors during a submaximal isometric contraction. Ten subjects performed a fatiguing contraction to task failure at 20% of maximal voluntary contraction force. EMG activity was recorded in biceps brachii, brachialis, and brachioradialis muscles using ...
متن کاملAnalysis of intramuscular electromyogram signals.
Intramuscular electromyographic (EMG) signals are detected with needles or wires inserted into muscles. With respect to non-invasive techniques, intramuscular electromyography has high selectivity for individual motor unit action potentials and is thus used to measure motor unit activity. Decomposition of intramuscular signals into individual motor unit action potentials consists in detection a...
متن کاملSequential estimation of intramuscular EMG model parameters for prosthesis control
EMG signals are an image of the control from the central nervous system transmitted to muscles. Intramuscular EMG signals are collected directly in muscles. The collected data contain information on the neural control of the muscle. This information can be used for controlling external devices (myoelectric control), however realtime processing of intramuscular EMG signals is complex. The aim of...
متن کاملIntramuscular EMG Decomposition Basing on Motor Unit Action Potentials Detection and Superposition Resolution
A novel electromyography (EMG) signal decomposition framework is presented for the thorough and precise analysis of intramuscular EMG signals. This framework first detects all of the active motor unit action potentials (MUAPs) and assigns single MUAP segments to their corresponding motor units. MUAP waveforms that are found to be superimposed are then resolved into their constituent single MUAP...
متن کامل