Improved micromethod for determination of underivatized clonazepam in serum by gas chromatography.
نویسندگان
چکیده
We describe a gas-chromatographic micromethod, with use of a solid injection system and an electron capture detector, for determination of underivatized clonazepam in serum. Vigorous mixing of 100 microliter of serum with 20 microliter of borate buffer (pH 9.0) and 100 microliter of a cyclohexane/dichloromethane mixture (4/6 by vol) containing methyl nitrazepam as internal standard suffices to extract 86% of the clonazepam into the organic layer. We obtained a linear response curve for clonazepam in serum in the concentration range 5 to 150 microgram/liter. The lowest detectable concentration by our method is about 1 microgram/liter of serum. Interference by several anticonvulsant drugs, metabolites, and related compounds was investigated. The assay is simple, rapid, and suitable for clinical routine determination of clonazepam in serum in therapeutic concentrations. We illustrate the steady-state concentration of clonazepam in serum during chronic oral administration to 28 patients.
منابع مشابه
Micromethod for determination of diazepam by electron-capture gas-liquid chromatography.
We used 100 microliters of plasma for the determination of diazepam. After the internal standard, prazepam, is added, the serum is directly extracted with diethyl ether, the extract is evaporated, the residue is dissolved in ethanol, and the drug is measured by gas-liquid chromatography, with use of an electron capture detector. With this procedure, 2.5 ng of diazepam in the sample can be speed...
متن کاملDetermination of Isosorbide Dinitrate in Serum by Gas Chromatography with New Generation of Electron Capture Detector and its Application in Pharmacokinetic Study
Isosorbide dinitrate (ISDN) is an effective drug in treatment of angina pectoris. In this study a new generation of electron capture detector (non-radioactive) with a short, non-polar and wide-bore column was used for analysis of ISDN in human serum. ISDN was extracted from serum by a mixture of ether and ethyl acetate and concentrated at room temperature. The method was linear between 5-50...
متن کاملDetermination of Isosorbide Dinitrate in Serum by Gas Chromatography with New Generation of Electron Capture Detector and its Application in Pharmacokinetic Study
Isosorbide dinitrate (ISDN) is an effective drug in treatment of angina pectoris. In this study a new generation of electron capture detector (non-radioactive) with a short, non-polar and wide-bore column was used for analysis of ISDN in human serum. ISDN was extracted from serum by a mixture of ether and ethyl acetate and concentrated at room temperature. The method was linear between 5-50...
متن کاملAn improved micromethod for theophylline determination by reversed-phase liquid chromatography.
We describe an improved micro-scale method for determining serum theophylline by reversed-phase liquid chromatography. Samples are deproteinized with two volumes of methanol containing beta-hydroxyethyltheophylline as an internal standard. The supernate is chromatographed with a methanol/sodium acetate buffer (15/85 by vol) mobile phase, and the amount of theophylline is calculated from the rat...
متن کاملMicromethod for measuring hexachlorophene in whole blood by gas-liquid chromatography.
We describe a micromethod for measuring hexachlorophene by use of gas-liquid chromatography with a 63Ni electron capture detector. The procedure requires 100 micronl of blood for extractions of hexachlorophene, and dichlorophene is added as an internal standard. CV is 3.4% over the concentration range of 500 to 1300 microng of hexachlorophene per liter of whole blood. This procedure permits rep...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 24 10 شماره
صفحات -
تاریخ انتشار 1978