Pressurised aerosol deposition in the human lung with and without an "open" spacer device.
نویسندگان
چکیده
A radiotracer technique has been used to assess aerosol delivery from a pressurised metered dose inhaler, used both with and without a 10 cm cylindrical spacer attachment (Syncroner), which has an open section in its upper surface. The radionuclide technetium-99m (99mTc) was added to sodium cromoglycate in a canister (Intal inhaler; 1 mg/puff); in vitro studies with a multistage liquid impinger showed that the radiolabel acted as a marker for the presence of drug over a wide range of particle sizes. Ten healthy volunteers were studied after they had inhaled from (1) a metered dose inhaler alone (slow inhaled flow rate, about 25 l/min); (2) metered dose inhaler plus spacer (slow flow rate); and (3) metered dose inhaler plus spacer (fast inhaled flow rate, about 100 l/min). Inhalation was coordinated with firing the spray and was followed by 10 seconds' breath holding. With the metered dose inhaler alone a mean 11.0% (SEM 1.4%) of the dose reached the lungs, compared with significantly higher doses for slow (16.1% (2.2%] and fast (13.3% (1.7%] inhalations through the spacer. The distribution pattern within the lungs was significantly more peripheral after slow inhalation. Oropharyngeal deposition was halved by the spacer. The open spacer should teach patients good coordination and delivers more aerosol to the lungs than a correctly used metered dose inhaler.
منابع مشابه
Improvement of pressurised aerosol deposition with Nebuhaler spacer device.
The effect on aerosol deposition from a pressurised metered dose inhaler of a 750 cm3 spacer device with a one way inhalation valve (Nebuhaler, Astra Pharmaceuticals) was assessed by means of an in vivo radiotracer technique. Nine patients with obstructive lung disease took part in the study. The pattern of deposition associated with use of a metered dose inhaler alone was compared with that ac...
متن کاملEffect of a spacer on pulmonary aerosol deposition from a jet nebuliser during mechanical ventilation.
BACKGROUND Several factors have been identified which improve nebulised aerosol delivery in vitro. One of these is the addition of a spacer to the ventilator circuit which improves aerosol delivery from a jet nebuliser to a model lung by approximately 30%. The current study was designed to demonstrate whether similar improvements could be demonstrated in vivo. METHODS Ten patients (seven men)...
متن کاملLung deposition of aerosol--a comparison of different spacers.
AIMS To investigate (1) aerosol lung deposition obtained from two small volume conventional spacers (Babyhaler and Aerochamber) and a home made spacer (modified 500 ml plastic cold drink bottle); (2) the effect of using a face mask or mouthpiece; and (3) the relation between age and pulmonary deposition. METHODS Lung deposition of aerosolised technetium-99m DTPA inhaled via spacer was measure...
متن کامل[Evaluation of the influence of patient age and spacer device volume on aerosol lung deposition].
OBJECTIVE To evaluate the efficacy of three frequently used spacer devices to deliver aerosol to the lung, and to compare radioaerosol deposition with each device in different age groups. METHODS Nine healthy, non-smoking volunteers were recruited: three adults and six children, including three toddlers and three school age children. Qualitative and semi-quantitative analysis of radioaerosol ...
متن کاملSpacer inhalation technique and deposition of extrafine aerosol in asthmatic children.
The aim of the present study was to measure airway, oropharyngeal and gastrointestinal deposition of (99m)Tc-labelled hydrofluoroalkane-beclomethasone dipropionate after inhalation via a pressurised metered-dose inhaler and spacer (Aerochamber Plus) in asthmatic children. A group of 24 children (aged 5-17 yrs) with mild asthma inhaled the labelled drug. A total of 12 children took five tidal br...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Thorax
دوره 44 9 شماره
صفحات -
تاریخ انتشار 1989