Influence of hematocrit, blood gas tensions, and pH on pressure-flow relations in the isolated canine lung.

نویسندگان

  • D Bucens
  • M C Pain
چکیده

An isolated perfused canine lung preparation in which determinants of vascular caliber could be individually controlled was developed. The relation of pulmonary arterial (Pa), venous (PV), and alveolar (PA) pressures was such that Pa greater than PA greater than PV throughout the whole lung. The addition of isoprenaline to the perfusate abolished vascular reactivity. Once stability was reached, vascular cross-sectional area remained acceptably constant for 2.25 hours as judged by normalized conductance. The influence of perfusate hematocrit, blood gas tensions, and pH on pressure-flow relations was then studied in 15 isolated canine lungs. The hematocrit-vascular conductance relation was derived at constant perfusion pressure. Conductance varied linearly with hematocrit over a range of 16.5 to 89.5%. Mean pulmonary arterial blood gas tensions were: PO2 = 121 mm Hg, PCO2 = 28 mm Hg, and pH = 7.46. Acute respiratory acidosis (PO2 = 30 mm Hg, PCO2 = 81 mm Hg, pH = 7.17) and lactic acidosis and hypoxemia (PO2 = 32 mm Hg, PCO2 = 21 mm Hg, pH = 6.96) did not significantly alter this relation. Transformation of the conductance-hematocrit data indicated that hematocrit was the most important determinant of relative apparent viscosity of the blood. Both acute respiratory and lactic acidosis failed to significantly increase relative viscosity within the range of hematocrit usually found in secondary polycythemia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hemodilution during venous gas embolization improves gas exchange, without altering V(A)/Q or pulmonary blood flow distributions.

BACKGROUND Isovolemic anemia results in improved gas exchange in rabbits with normal lungs but in relatively poorer gas exchange in rabbits with whole-lung atelectasis. In the current study, the authors characterized the effects of hemodilution on gas exchange in a distinct model of diffuse lung injury: venous gas embolization. METHODS Twelve anesthetized rabbits were mechanically ventilated ...

متن کامل

The Interaction between Trolox and 4,4’-diisothiocyanatostilbene-2,2’-disulfonic Acid on Hypoxic Pulmonary Vasoconstriction in the Isolated Rabbit Lung

Background: The mechanism of hypoxic pulmonary vasoconstriction (HPV) is still debatable. It has been proposed that reactive oxygen species (ROS) might be involved in HPV. However, there is no special transporter for superoxide anion in the cell membrane and it may release from the cells via anion exchanger. Therefore, the aim of this study was to investigate the interaction of ROS and anion ex...

متن کامل

Gas Flow Metering Using the PSO Optimized Interval Type- 2 Fuzzy Neural Network

Orifice flow meter is one of the most common devices in industry which is used for measuring the gas flow. This system includes an orifice plate, temperature and pressure transmitters, and a flow computer. The flow computer is used for collecting information related to temperature, pressure, and their differences under various conditions. Also the flow computer can calculate the flow rate of ga...

متن کامل

Sustained Hypoxic Pulmonary Vasoconstriction in the Isolated Perfused Rat Lung: Effect of α1-adrenergic Receptor Agonist

Background: Alveolar hypoxia induces monophasic pulmonary vasoconstriction in vivo, biphasic vasoconstriction in the isolated pulmonary artery, and controversial responses in the isolated perfused lung. Pulmonary vascular responses to sustained alveolar hypoxia have not been addressed in the isolated perfused rat lung. In this study, we investigated the effect of sustained hypoxic ventilation o...

متن کامل

Optimal hematocrit for oxygenation of canine intestine.

To determine the direct effects of hematocrit on intestinal oxygen consumption and to determine whether an optimal hematocrit exists for intestinal oxygenation, we perfused isolated canine gut loops at a constant pressure (120 mm Hg) and varied hematocrit from 80% to 10%. As hematocrit fell, blood flow rose while arterial oxygen content fell. The regression of blood flow on hematocrit was linea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 37 5  شماره 

صفحات  -

تاریخ انتشار 1975