Improved performance of comprehensive two-dimensional HPLC separation of traditional Chinese medicines by using a silica monolithic column and normalization of peak heights.
نویسندگان
چکیده
Performance of comprehensive two-dimensional liquid chromatography system is greatly improved than we reported previously by using a silica monolithic column as for the second dimensional separation. Due to the increase of the elution speed on the second dimensional monolithic column, the first dimensional column efficiency and analysis rate can be greatly improved as comparing with conventionally second dimensional column. The developed system was applied to analysis of methanol extraction of two umbelliferae herbs Ligusticum chuanxiong Hort. and Angelica sinensis (Oliv.) Diels by using CN column as for the first dimensional separation and a silica monolithic ODS column for the second dimensional separation, and the obtained three-dimensional chromatograms were treated by normalization of peak heights with the value of the highest peak or setting a certain value using a software written in-house. It was observed that much more peaks for low-abundant components in TCM extract can clearly be detected here than we reported before, due to the large difference for the amount of components in TCMs' extract. With the above improvements in separation performance and data treatment, totally about 120 components in methanol extraction of Rhizoma chuanxiong and 100 in A. sinensis were separated with UV detection within 130 min. This result meant that both the number of peaks detected increase twice but the analysis time decrease twice if comparing with the previously reported result.
منابع مشابه
Octadecylated silica monolith capillary column with integrated nanoelectrospray ionization emitter for highly efficient proteome analysis.
An improved strategy for the preparation of octadecylated silica monolith capillary column with high homogeneity was proposed. Column performance was evaluated by nanoscale HPLC. The design for constructing an integrated nanoelectrospray emitter on the octadecylated silica monolith capillary column was first introduced. In comparison with the separated configuration where the emitter is connect...
متن کاملApplication of Monolithic Silica Column for HPLC Separation of Estrogens
A monolithic silica column has recently been widely used for HPLC separation analysis. Compared with the particle−packed column (conventional column), the monolithic silica column eluted the analyte with a smaller retention factor (k), lower pressure and satisfactory separation [1]. However, the monolithic silica column has not been widely used for the HPLC or LC/MS analysis of steroids. These ...
متن کاملEnhanced sequence coverage in tryptic fragment analysis by two-dimensional HPLC/MS using a monolithic silica capillary column.
The HPLC/MS system, in which a monolithic silica capillary column is directly connected to an electronspray-ionization mass spectrometer, showed superior performance at high mobile phase linear velocity. A two-dimensional (2D) HPLC/MS system was established, using an ion-exchange particle-packed capillary column at the first dimension and a monolithic silica capillary column at the second dimen...
متن کاملBiological fingerprinting analysis of the traditional Chinese prescription Longdan Xiegan Decoction by on/off-line comprehensive two-dimensional biochromatography.
A comprehensive two-dimensional biochromatography method using a silica-bonded human serum albumin (HSA) column and a RP-HPLC column was developed for the biological fingerprinting analysis of bioactive components in a traditional Chinese medicine (TCM) prescription, Longdan Xiegan Decoction (LXD). The biochromatography with HSA-immobilized stationary phase was applied to study the interaction ...
متن کاملSeparation of polyprenol and dolichol by monolithic silica capillary column chromatography.
We attempted an analysis of naturally occurring polyprenol and dolichol using a monolithic silica capillary column in HPLC. First, the separation of the polyprenol mixture alone was performed using a 250 x 0.2 mm inner diameter (ID) octadecylsilyl (ODS)-monolithic silica capillary column. The resolution of the separation between octadecaprenol (prenol 18) and nonadecaprenol (prenol 19) exceeded...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatography. A
دوره 1092 2 شماره
صفحات -
تاریخ انتشار 2005