0356 - Vertebroplasty: the Biomechanical Effect of Cement Volume
ثبت نشده
چکیده
INTRODUCTION Osteoporotic vertebral compression fractures (OVFs) can be the source of substantial pain and deformity, leading to disability and poor quality of life. In certain instances, percutaneous transpedicular vertebroplasty (PVP) is used in place of nonoperative therapy to treat OVFs. PVP typically consists of passing a 10to 15-gauge cannula percutaneously through each pedicle and injecting polymethylmethacrylate (PMMA) cement into the cancellous bone of the vertebral body (VB) to provide strength and support. The technique reportedly results in good pain relief with a low complication rate. Because PVP is a relatively new technique, many questions regarding the procedure remain. The mechanical stabilization afforded by the injection of cement may be responsible for the palliative effect of PVP. How much cement is needed to effect stabilization is unknown. When PVP is used to treat osteolytic metastases and myeloma, there is no correlation between cement volume and pain relief. It is unknown if a similar lack of correlation exists for OVFs treated with PVP. The purpose of this study was to determine what volume of cement is necessary to restore VB strength and stiffness to prefracture values. The four injection volumes investigated were 2, 4, 6, and 8 cc. MATERIALS AND METHODS Twelve VBs (T6-L5) from each of five fresh spines (60 VBs total) were harvested from female cadavers (80.6 ± 6.8 years old) and evaluated for osteoporosis (average T score = -6.1 ± 1.4) using the Dual Energy X-ray Absorptiometry method (DEXA; Lunar DPX-1Q, Lunar Corp., Madison, WI). We disarticulated the vertebrae, excised their discs, and removed the posterior elements to more readily facilitate mechanical testing. Using a Latin square design, the VBs were segregated into three regional groups of four levels each: thoracic (T6-T9), thoracolumbar (T10-L1), and lumbar (L2-L5). Within each region, the VBs were assigned to receive one of four cement volumes. In this manner, the number of VB specimens from each level and each spine were evenly distributed among the fill-volume groups, while minimizing the effect of donor and vertebral level. The VBs were wrapped in saline-soaked gauze, sealed in plastic bags, and stored at -20°C until the day before testing. All specimens were thawed at room temperature (20°C) 24 hours before testing. An impression of the end plates of each vertebra was made using a common epoxy resin (Fastray, Bosworth, Skokie, IL). Each VB was floated in its sealed plastic bag in a water bath (37°C) for at least 1 hour before mechanical testing. Anterior, posterior, and right and left lateral VB heights were measured using digital calipers accurate to 0.01 mm. Each VB was seated between its respective impressions, placed between platens on an Instron materials testing machine, and compressed at a rate of 5 mm/min. Compression was applied to the superior platen along the central axis of the VB until failure occurred. Failure was defined as a precipitous decrease in load with increasing compression of the VB. Strength was defined as load at failure and stiffness was defined as the slope of the force versus deformation curve between 448 and 1112 N. After the simulated compression fracture was created, an 11-gauge cannula was inserted through each pedicle. Orthocomp cement (Orthovita, Malvern, PA) was prepared per manufacturer’s recommendations at room temperature and a bolus was then injected through each cannula into the interior of each VB, resulting in an interior fill of 2, 4, 6, or 8 cc, respectively. Orthocomp, a new bioactive cement composed of Bis-GMA/Bis-EMA resin reinforced with inert and bioactive fillers, was developed to overcome some of the deficiencies of current cements used in PVP. After injection, each VB was wrapped in saline-soaked gauze, sealed in a plastic bag, and floated in a bath (37°C) for at least 1 hour to simulate physiologic conditions and to allow the bone cement to cure. VB heights were measured as before and specimens were then recompressed according to the initial crush protocol. Stiffness was calculated as before. Posttreatment strength was defined as the load corresponding to the deformation at which the initial failure occurred. Using linear regression, we checked for significance (P < 0.05) in the relationship between the volume of cement and the pretreatment vs posttreatment difference in strength and stiffness. RESULTS The regression analysis suggested that to restore initial VB strength, 7.7, 5.0, and 2.9 cc should be injected in the lumbar, thoracolumbar, and thoracic regions, respectively (Fig. 1). Similarly, to restore VB stiffness, 8.8, 11.1, and 6.7 cc should be injected in the lumbar, thoracolumbar, and thoracic regions, respectively (Fig. 2). Only for the thoracolumbar group was the relationship between cement volume and strength restoration significantly correlated, albeit weakly (r =.23). For all other groups, we found no significant relationship between cement volume and restoration of stiffness or strength. This result is likely due to the sample size (n = 5) and the associated variance in the data. DISCUSSION The results of this study provide practitioners of PVP some guidance regarding the volume of cement required to restore VB strength and stiffness. Clinically, the pain relief experienced with PVP may be due to stabilization of the VB and prevention of micromotion at the fracture site; thus, restoring mechanical property may not be required. If this is the case, our analysis is an overestimate of the volume of cement required. Conversely, we used Orthocomp, which is materially stronger and stiffer than PMMA. Thus, to obtain similar results using PMMA, greater volumes may need to be injected compared with the volumes of Orthocomp.
منابع مشابه
Effect of Bone Cement Volume and Stiffness on Occurrences of Adjacent Vertebral Fractures after Vertebroplasty
OBJECTIVE The purpose of this study is to find the optimal stiffness and volume of bone cement and their biomechanical effects on the adjacent vertebrae to determine a better strategy for conducting vertebroplasty. METHODS A three-dimensional finite-element model of a functional spinal unit was developed using computed tomography scans of a normal motion segment, comprising the T11, T12 and L...
متن کاملDoes Balloon Kyphoplasty Deliver More Cement Safely into Osteoporotic Vertebrae with Compression Fractures Compared with Vertebroplasty? A Study in Vertebral Analogues
Study Design A biomechanical and radiographic study using vertebral analogues. Objectives Kyphoplasty and vertebroplasty are widely used techniques to alleviate pain in fractures secondary to osteoporosis. However, cement leakage toward vital structures like the spinal cord can be a major source of morbidity and even mortality. We define safe cement injection as the volume of the cement injecte...
متن کامل0319 - Effects of Bone Cement Volume and Distribution on Vertebral Body Stiffness Recovery after Vertebroplasty
Introduction Vertebroplasty is a new therapeutic method which by way of filling bone cement in the vertebral body stabilizes the vertebra. This technique requires a relatively short and less invasive surgery, and has produced excellent short-term clinical results in terms of pain relief . Biomechanical studies have shown that cement augmentation can stabilize the damaged vertebral body in terms...
متن کاملDevelopment of calcium phosphate cement for the augmentation of traumatically fractured porcine specimens using vertebroplasty
The study aim was to develop and apply an experimental technique to determine the biomechanical effect of polymethylmethacrylate (PMMA) and calcium phosphate (CaP) cement on the stiffness and strength of augmented vertebrae following traumatic fracture. Twelve burst type fractures were generated in porcine three-vertebra segments. The specimens were randomly split into two groups (n=6), imaged ...
متن کاملVertebroplasty: Patient and treatment variations studied through parametric computational models☆
BACKGROUND Vertebroplasty is increasingly used in the treatment of vertebral compression fractures. However there are concerns that this intervention may lead to further fractures in the adjacent vertebral segments. This study was designed to parametrically assess the influence of both treatment factors (cement volume and number of augmentations), and patient factors (bone and disc quality) on ...
متن کاملA biomechanical investigation of vertebroplasty in osteoporotic compression fractures and in prophylactic vertebral reinforcement.
STUDY DESIGN Cadaveric single vertebrae were used to evaluate vertebroplasty as a prophylactic treatment and as an intervention for vertebral compression fractures. OBJECTIVE To investigate the biomechanical characteristics of prophylactic reinforcement and postfracture augmentation of cadaveric vertebrae. SUMMARY OF BACKGROUND DATA Percutaneous vertebroplasty is a treatment option for oste...
متن کامل