18F-Mefway PET Imaging of Serotonin 1A Receptors in Humans: A Comparison with 18F-FCWAY
نویسندگان
چکیده
INTRODUCTION The purpose of this research is to evaluate the prospects for the use of 4-(trans-18F-fluoranylmethyl)-N-[2-[4-(2-methoxyphenyl)piperazin-1-yl]ethyl]-N-pyridin-2-ylcyclohexane-1-carboxamide (18F-Mefway) in comparison to 18F-trans-4-fluoro-N-2-[4-(2-methoxyphenyl)piperazin-1-yl]ethyl]-N-(2-pyridyl)cyclohexanecarboxamide (18F-FCWAY) for the quantification of 5-HT1A receptors in human subjects. METHOD Five healthy male controls were included for two positron emission tomography (PET) studies: 18F-FCWAY PET after the pretreatment with 500 mg of disulfiram and two months later, 18F-Mefway PET without disulfiram. Regional time-activity curves (TACs) were extracted from nine cortical and subcortical regions in dynamic PET images. Using cerebellar cortex without vermis as reference tissue, in vivo kinetics for both radioligands were compared based on the distribution volume ratio (DVR) calculated by non-invasive Logan graphical analysis and area under the curve ratio of the TACs (AUC ratio). RESULT Although the pattern of regional uptakes in the 18F-Mefway PET was similar to that of the 18F-FCWAY PET (highest in the hippocampus and lowest in the cerebellar cortex), the amount of regional uptake in 18F-Mefway PET was almost half of that in 18F-FCWAY PET. The skull uptake in 18F-Mefway PET was only 25% of that in 18F-FCWAY PET with disulfiram pretreatment. The regional DVR values and AUC ratio values for 18F-Mefway were 17-40% lower than those of 18F-FCWAY. In contrast to a small overestimation of DVR values by AUC ratio values (< 10%) in 18F-FCWAY PET, the overestimation bias of AUC ratio values was much higher (up to 21%) in 18F-Mefway PET. CONCLUSION As 18F-Mefway showed lower DVR values and greater overestimation bias of AUC ratio values, 18F-Mefway may appear less favorable than 18F-FCWAY. However, in contrast to 18F-FCWAY, the resistance to in vivo defluorination of 18F-Mefway obviates the need for the use of a defluorination inhibitor. Thus, 18F-Mefway may be a good candidate PET radioligand for 5-HT1A receptor imaging in human.
منابع مشابه
Correction: 18F-Mefway PET Imaging of Serotonin 1A Receptors in Humans: A Comparison with 18F-FCWAY
In the Funding section, the grant number from the funder Yonsei University College of Medicine is listed incorrectly. The correct grant number is: 6-2008-0237. access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
متن کاملSynthesis and biologic evaluation of a novel serotonin 5-HT1A receptor radioligand, 18F-labeled mefway, in rodents and imaging by PET in a nonhuman primate.
UNLABELLED Serotonin 5-HT1A receptors have been implicated in disorders of the central nervous system and, therefore, are being studied by PET. Efforts are under way to improve in vivo stability of 5-HT1A agents currently in human use (11C-labeled N-(2-[4-(2-methoxyphenyl)-1-piperazinyl]ethyl-N-(2-pyridinyl)cyclohexanecarboxamide [11C-WAY-100635], 4-(2'-methoxyphenyl)-1-[2'-(N-2''-pyridinyl)-p-...
متن کاملPET imaging of brain 5-HT1A receptors in rat in vivo with 18F-FCWAY and improvement by successful inhibition of radioligand defluorination with miconazole.
UNLABELLED 18F-FCWAY (18F-trans-4-fluoro-N-(2-[4-(2-methoxyphenyl) piperazin-1-yl)ethyl]-N-(2-pyridyl)cyclohexanecarboxamide) is useful in clinical research with PET for measuring serotonin 1A (5-HT1A) receptor densities in brain regions of human subjects but has significant bone uptake of radioactivity due to defluorination. The uptake of radioactivity in skull compromises the accuracy of meas...
متن کاملReduced serotonin type 1A receptor binding in panic disorder.
Recent animal models suggest that disturbances in serotonin type-1A receptor (5-HT(1A)R) function may contribute to chronic anxiety, although it is not clear at all whether such models constitute relevant models for panic disorder (PD) in humans. The selective 5-HT(1A)R radioligand [18F]trans-4-fluoro-N-2-[4-(2-methoxyphenyl)piperazin-1-yl]ethyl]-N-(2-pyridyl)cyclohexanecarboxamide (FCWAY) perm...
متن کاملMarmoset Serotonin 5-HT1A Receptor Mapping with a Biased Agonist PET Probe 18F-F13714: Comparison with an Antagonist Tracer 18F-MPPF in Awake and Anesthetized States
BACKGROUND In vivo mapping by positron emission tomography of the serotonin 1A receptors has been hindered by the lack of suitable agonist positron emission tomography probes. 18F-labeled F13714 is a recently developed biased agonist positron emission tomography probe that preferentially targets subpopulations of serotonin 1A receptors in their "active state," but its brain labeling pattern in ...
متن کامل