Self-powered switch-controlled nucleic acid extraction system.

نویسندگان

  • Kyungsup Han
  • Yong-Jin Yoon
  • Yong Shin
  • Mi Kyoung Park
چکیده

Over the past few decades, lab-on-a-chip (LOC) technologies have played a great role in revolutionizing the way in vitro medical diagnostics are conducted and transforming bulky and expensive laboratory instruments and labour-intensive tests into easy to use, cost-effective miniaturized systems with faster analysis time, which can be used for near-patient or point-of-care (POC) tests. Fluidic pumps and valves are among the key components for LOC systems; however, they often require on-line electrical power or batteries and make the whole system bulky and complex, therefore limiting its application to POC testing especially in low-resource setting. This is particularly problematic for molecular diagnostics where multi-step sample processing (e.g. lysing, washing, elution) is necessary. In this work, we have developed a self-powered switch-controlled nucleic acid extraction system (SSNES). The main components of SSNES are a powerless vacuum actuator using two disposable syringes and a switchgear made of PMMA blocks and an O-ring. In the vacuum actuator, an opened syringe and a blocked syringe are bound together and act as a working syringe and an actuating syringe, respectively. The negative pressure in the opened syringe is generated by a restoring force of the compressed air inside the blocked syringe and utilized as the vacuum source. The Venus symbol shape of the switchgear provides multiple functions including being a reagent reservoir, a push-button for the vacuum actuator, and an on-off valve. The SSNES consists of three sets of vacuum actuators, switchgears and microfluidic components. The entire system can be easily fabricated and is fully disposable. We have successfully demonstrated DNA extraction from a urine sample using a dimethyl adipimidate (DMA)-based extraction method and the performance of the DNA extraction has been confirmed by genetic (HRAS) analysis of DNA biomarkers from the extracted DNAs using the SSNES. Therefore, the SSNES can be widely used as a powerless and disposable system for DNA extraction and the syringe-based vacuum actuator would be easily utilized for diverse applications with various microchannels as a powerless fluidic pump.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two self-powered energy harvesting interfaces based on the optimized synchronous electric charge extraction technique

Optimized synchronous electric charge extraction (OSECE) interface is a load weakly-dependant circuit, which is a favorable characteristic for piezoelectric wideband vibration energy harvesting. However, it introduces synchronous switches that need to be selfpowered in a stand-alone system. This paper presents the design and experimental testing of two self-powered approaches for the OSECE tech...

متن کامل

Comparative Study of Extracted Nucleic Acid from Escherichia coli by Two Methods Phenol-chloroform and Extraction Using Magnetic Nanoparticle

Background: The most important researches in molecular and genetic engineering fields are the finding of optimal methods for extraction of the genomic content of microorganisms and cells using them, can achieve the most amount and purity with the least time and cost. There are several methods for the extraction of bacterial DNA and the use of magnetic nanoparticles is one of the novel methods o...

متن کامل

Self-powered integrated microfluidic point-of-care low-cost enabling (SIMPLE) chip

Portable, low-cost, and quantitative nucleic acid detection is desirable for point-of-care diagnostics; however, current polymerase chain reaction testing often requires time-consuming multiple steps and costly equipment. We report an integrated microfluidic diagnostic device capable of on-site quantitative nucleic acid detection directly from the blood without separate sample preparation steps...

متن کامل

Self-healing in payment switches with a focus on failure detection using State Ma- chine-based approaches

Composition, change and complexity have attracted ev- eryone’s attention towards Self-Adaptive systems. These systems, inspired by the human body, are capable of adapting to changes in the inner and outer environment. The main objective of this study is to achieve a more con- venient availability for e-banking services in the payment switch, using self-healing systems and focusing on the failur...

متن کامل

Self-healing in payment switches with a focus on failure detection using State Ma- chine-based approaches

Composition, change and complexity have attracted ev- eryone’s attention towards Self-Adaptive systems. These systems, inspired by the human body, are capable of adapting to changes in the inner and outer environment. The main objective of this study is to achieve a more con- venient availability for e-banking services in the payment switch, using self-healing systems and focusing on the failur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Lab on a chip

دوره 16 1  شماره 

صفحات  -

تاریخ انتشار 2016