Calibration of dissipation factor standards

نویسندگان

  • Eric D. Simmon
  • Gerald J. FitzPatrick
  • Oskars Petersons
چکیده

Working standards for dissipation factor (D) obtained by connecting a shielded three-tenninal capacitor in series with a shielded precision resistor have been developed for calibration purposes. Precision conductance boxes have been built for use with a single three-tenninallOOO pF gas capacitor standard to create dissipation factor standards having values from 2 x 10-5 to 1 X 10-2. The design and testing of these D standards, including precautions in their construction and use, is presented. Calibration procedures using the NIST high voltage capacitance bridge and the measurement uncertainties are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calibration of Voltage Transformers and High- Voltage Capacitors at NIST

The National Institute of Standards and Technology (NIST) calibration service for voltage transformers and high-voltage capacitors is described. The service for voltage transformers provides measurements of ratio correction factors and phase angles at primary voltages up to 170 kV and secondary voltages as low as 10 V at 60 Hz. Calibrations at frequencies from 50-400 Hz are available over a mor...

متن کامل

Test Structures and Techniques for On-Wafer CMOS TRL Calibration

In this paper, we demonstrate for the first time a TRL calibration kit fabricated in CMOS technology. To fulfill a basic requirement of high probe-isolation of the TRL method, we have based all fabricated calibration standards on a shield-based measuring fixture that heavily reduces the effects of the semiconducting substrate. We analyze the electrical performance of the standards, including th...

متن کامل

Standard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties

Background: Absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. These chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. The secondary standard dosimetry laboratory of Iran (SSDL) has the duty of calibrating the ionization chambers used in radiotherapy centers in Iran. Materials and Methods...

متن کامل

Steel Plate Characteristic Effecting on Composite Coupled Beam at Concrete Shear Wall

Composite couple beams are the concrete elements consisting of longitudinal bars and steel plate, therefore suitable for shear transferring in couple shear walls with arranged gates in its height. In this paper, after modeling couple beams with and without steel plates with F.E methods and calibration the models with experimental results, effects of parameters such as thickness, height, length ...

متن کامل

The Effect of Viscous Dissipation and Variable Properties on Nanofluids Flow in Two Dimensional Microchannels

Laminar two dimensional forced convective heat transfer of Al2O3 –water nanofluid in a horizontal microchannel has been studied numerically, considering axial conduction, viscous dissipation and variable properties effects. The existing criteria in the literature for considering viscous dissipation in energy equation are compared for different cases and the most proper one is applied for the re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • IEEE Trans. Instrumentation and Measurement

دوره 48  شماره 

صفحات  -

تاریخ انتشار 1999