‘‘Smart’’ Base Isolation Systems

نویسندگان

  • J. C. Ramallo
  • E. A. Johnson
چکیده

A ‘‘smart’’ base isolation strategy is proposed and shown to effectively protect structures against extreme earthquakes without sacrificing performance during the more frequent, moderate seismic events. The proposed smart base isolation system is composed of conventional low-damping elastomeric bearings and ‘‘smart’’ controllable ~semiactive! dampers, such as magnetorheological fluid dampers. To demonstrate the advantages of this approach, the smart isolation system is compared to lead-rubber bearing isolation systems. The effectiveness of the isolation approaches are judged based on computed responses to several historical earthquakes scaled to various magnitudes. The limited performance of passive systems is revealed and the potential advantages of smart dampers are demonstrated. Twoand six-degree-of-freedom models of a base-isolated building are used as a test bed in this study. Smart isolation is shown to achieve notable decreases in base drifts over comparable passive systems with no accompanying increase in base shears or in accelerations imparted to the superstructure. In contrast to passive lead-rubber bearing systems, the adaptable nature of the smart damper isolation system provides good protection to both the structure and its contents over a wide range of ground motions and magnitudes. DOI: 10.1061/~ASCE!0733-9399~2002!128:10~1088! CE Database keywords: Damping; Base isolation; Earthquakes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

OPTIMAL SMART BASE ISOLATION SYSTEM FOR MULTIPLE EARTHQUAKES

Hybrid control system composed of a base isolation system and a magneto-rheological damper so-called smart base isolation is one of effective semi-active control system in controlling the seismic response of structures. In this paper, a design method is proposed for designing the smart base isolation system in order to achieve an effective performance under multiple earthquakes. The base mass, ...

متن کامل

‘‘Smart’’ Base Isolation Strategies Employing Magnetorheological Dampers

One of the most successful means of protecting structures against severe seismic events is base isolation. However, optimal design of base isolation systems depends on the magnitude of the design level earthquake that is considered. The features of an isolation system designed for an El Centro-type earthquake typically will not be optimal for a Northridge-type earthquake and vice versa. To be e...

متن کامل

Seismic Response Reduction of Structures using Smart Base Isolation System

In this study, control performance of a smart base isolation system consisting of a friction pendulum system (FPS) and a magnetorheological (MR) damper has been investigated. A fuzzy logic controller (FLC) is used to modulate the MR damper so as to minimize structural acceleration while maintaining acceptable base displacement levels. To this end, a multi-objective optimization scheme is used t...

متن کامل

Automatic generation of smart earthquake-resistant building system: Hybrid system of base-isolation and building-connection

A base-isolated building may sometimes exhibit an undesirable large response to a long-duration, long-period earthquake ground motion and a connected building system without base-isolation may show a large response to a near-fault (rather high-frequency) earthquake ground motion. To overcome both deficiencies, a new hybrid control system of base-isolation and building-connection is proposed and...

متن کامل

Base Isolation Systems – A State of the Art Review According to Their Mechanism

Seismic isolation is a method to reduce the destructive effects of earthquakes on a structure in which the structure is separated from its foundation by devices called seismic isolators. As a result, the horizontal movements of the earthquake transmitted to the structure are reduced. The seismic isolation is used for both newly constructed structures as well as for retrofitting the existing bui...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002