Accuracy of zoomed digital image in the detection of periodontal bone defect: in vitro study.

نویسندگان

  • J A N D de Morais
  • C E Sakakura
  • L C M Loffredo
  • G Scaf
چکیده

OBJECTIVES (1) To evaluate the intraobserver agreement related to image interpretation and (2) to compare the accuracy of 100%, 200% and 400% zoomed digital images in the detection of simulated periodontal bone defects. METHODS Periodontal bone defects were created in 60 pig hemi-mandibles with slow-speed burs 0.5 mm, 1.0 mm, 1.5 mm, 2.0 mm and 3.0 mm in diameter. 180 standardized digital radiographs were made using Schick sensor and evaluated at 100%, 200% and 400% zooming. The intraobserver agreement was estimated by Kappa statistic (kappa). For the evaluation of diagnostic accuracy receiver operating characteristic (ROC) analysis was performed followed by chi-square test to compare the areas under ROC curves according to each level of zooming. RESULTS For 100%, 200% and 400% zooming the intraobserver agreement was moderate (kappa=0.48, kappa=0.54 and kappa=0.43, respectively) and there were similar performances in the discrimination capacity, with ROC areas of 0.8611 (95% CI: 0.7660-0.9562), 0.8600 (95% CI: 0.7659-0.9540), and 0.8368 (95% CI: 0.7346-0.9390), respectively, with no statistical significant differences (chi2-test; P=0.8440). CONCLUSIONS A moderate intraobserver agreement was observed in the classification of periodontal bone defects and the 100%, 200% and 400% zoomed digital images presented similar performances in the detection of periodontal bone defects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing the Accuracy of Cone Beam Computed Tomography,Digital Intraoral Radiography and Conventional Intraoral Radiography in the Measurement of Periodontal Bone Defects

Background and Aim: Cone beam computed tomography (CBCT) produces high-quality data in periodontal diagnosis and treatment planning. The aim of this study was to compare the accuracy of CBCT with intraoral digital and conventional radiography in the measurement of periodontal bone defects.  Methods and Materials: In this diagnostic research, two hundred and eighteen artificial osseous d...

متن کامل

بررسی و مقایسه دقت رادیوگرافی های پانورامیک، پری اپیکال و بایت وینگ در تعیین میزان تحلیل استخوان آلوئول در پریودنتیت

Introduction: The height of the alveolar bone, is normally maintained by equilibrium between bone formation and bone resorption, but in periodontal disease more destruction or lack of bone formation will reduce the alveolar bone height. However the radiography is important in diagnosis, treatment plan and detection of quality and quantity of the alveolar bone although the type of radiography is...

متن کامل

ارزیابی دقت رادیوگرافی بایت‌وینگ دیجیتال (CMOS) در سنجش تحلیل استخوان آلوئولار بین‌دندانی در دندان‌های خلفی

Background and ObjectiveRadiographic examination has an important role in diagnosis and treatment of periodontal patients, so this study was performed to determine the accuracy of digital bite wing (CMOS) radiography in alveolar bone resorption. Materials and Methods: This cross-sectional study was performed on 61 teeth of 16 periodontal patients referred to the periodontoloy department of R...

متن کامل

Comparison of Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography for Detection of Vertical Root Fractures with and without Gutta Percha

  Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics which most of the times occurs in endodontically treated teeth with root canal fillings such as gutta percha. Despite Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) which aid the diagnosis, artifacts has remained as a problem in VRF detection . ...

متن کامل

مقایسه دقت سه گیرنده تصویر دیجیتال و نرم افزار مربوط در تشخیص ضایعات پوسیدگی بین دندانی (مطالعه in vitro)

Background and purpose: The use of intraoral direct digital radiography has been possible only the past two decades. Controlled laboratory and clinical studies are needed to determine whether the new digital system changes the diagnosis, treatment and prognosis than the conventional methods. Purpose of this study is compare the diagnostic accuracy for the detection of approximal caries of three...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Dento maxillo facial radiology

دوره 35 3  شماره 

صفحات  -

تاریخ انتشار 2006