Construction and characterization of a high-flow, high-resolution ion mobility spectrometer for detection of explosives after personnel portal sampling.
نویسندگان
چکیده
A novel analysis of explosives via the coupling of an airline passenger personnel portal with a high-flow (HF), high-resolution (HR) ion mobility spectrometry (IMS) was shown for the first time. The HF-HR-IMS utilized a novel ion aperture grid design with a (63)Ni ionization source while operating at ambient pressure in the positive ion mode at 200 degrees C. The HF-HR-IMS response characteristics of 2,4,6-trinitrotoluene (TNT), 4,6-dinitro-o-cresol (4,6DNOC), and cyclo-1,3,5-trimethylene-2,4,6-trinitramine (RDX) were investigated. Modifications made to the HF-HR-IMS exhaust and ionization source created an 800% increase in the total ion current (TIC), from 0.85 to 6.8 nA. This translated into a 65% ion response increase for TNT when compared with a traditional IMS. A mixture of TNT and (4,6DNOC) was used to successfully demonstrate the resolving power of the species with similar reduced mobility constants (K(o)), 1.54 and 1.59, respectively. The reactant ion (H(2)O)(n)H(+), peak was also used to measure the resolving power of the spectrometer while varying the internal diameter of three different aperture openings from 1.00 to 3.54cm. This provided a resolving power range of 50-60, double that typically achievable by commercial IMS instruments. Most important, these changes made in this new instrumental design can be implemented to all existing and future IMS's to greatly enhance the achievable IMS resolving power.
منابع مشابه
DETECTION AND MEASUREMENT OF ACETONE IN THE BREATH OF DIABETICS BY ION MOBILITY SPECTROMETRY METHOD
Background: The ion mobility spectrometry (IMS) is an analytical technique that is widely used due to its high sensitivity and speed for the detection of ionized molecules in gas phase and under atmospheric pressure. Breath analysis is a new method for obtaining information about person's clinical conditions that is considered by researchers. Human exhaled air contains a variety of components s...
متن کاملDynamic planar solid phase microextraction-ion mobility spectrometry for rapid field air sampling and analysis of illicit drugs and explosives.
A preconcentration device that targets the volatile chemical signatures associated with illicit drugs and explosives (high and low) has been designed to fit in the inlet of an ion mobility spectrometer (IMS). This is the first reporting of a fast and sensitive method for dynamic sampling of large volumes of air using planar solid phase microextraction (PSPME) incorporating a high surface area f...
متن کاملCluster measurements at CLOUD using a high resolution ion mobility spectrometer- mass spectrometer combination
Mass spectrometry is powerful tool for environmental and atmospheric chemistry analysis. Modern mass spectrometers demonstrate low detection limits, high sensitivity, and high resolving power. However, such high performance is not always enough to identify ambient ion clusters due to the clusters braking at the atmospheric pressure-to-vacuum interface of mass spectrometer. This study presents a...
متن کاملFluorescent Nanofilms for Nitroaromatic Explosives Detection-Promises and Challenges
Fast and sensitive detection of nitro-aromatic explosives is of vital importance for finding hidden explosives in airport luggage or mails, screening of personnel, and detection of buried landmines [1-3]. A crucial example is the detection of trace amount of 2,4,6-trinitrotoluene (TNT), which is a typical nitro-aromatic explosives [ 4-8]. Various TNT detection methods are currently available, s...
متن کاملروشهای طیفسنجی در آنالیز همزمان مواد منفجره
Simultaneous analysis of explosives to identify, determine the purity and eliminate environmental pollution requires rapid, simple and cheap methods. Spectrophotometries method (UV-Vis), high-field proton nuclear magnetic resonance (1H-NMR), Raman spectroscopy and near infrared (NIR) are common methods that are applicable in two ways of direct and indirect in simultaneous analysis. In this poin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Talanta
دوره 57 1 شماره
صفحات -
تاریخ انتشار 2002