Validity and reliability of the PowerTap mobile cycling powermeter when compared with the SRM Device.

نویسندگان

  • W Bertucci
  • S Duc
  • V Villerius
  • J N Pernin
  • F Grappe
چکیده

The SRM power measuring crank system is nowadays a popular device for cycling power output (PO) measurements in the field and in laboratories. The PowerTap (CycleOps, Madison, USA) is a more recent and less well-known device that allows mobile PO measurements of cycling via the rear wheel hub. The aim of this study is to test the validity and reliability of the PowerTap by comparing it with the most accurate (i.e. the scientific model) of the SRM system. The validity of the PowerTap is tested during i) sub-maximal incremental intensities (ranging from 100 to 420 W) on a treadmill with different pedalling cadences (45 to 120 rpm) and cycling positions (standing and seated) on different grades, ii) a continuous sub-maximal intensity lasting 30 min, iii) a maximal intensity (8-s sprint), and iiii) real road cycling. The reliability is assessed by repeating ten times the sub-maximal incremental and continuous tests. The results show a good validity of the PowerTap during sub-maximal intensities between 100 and 450 W (mean PO difference -1.2 +/- 1.3 %) when it is compared to the scientific SRM model, but less validity for the maximal PO during sprint exercise, where the validity appears to depend on the gear ratio. The reliability of the PowerTap during the sub-maximal intensities is similar to the scientific SRM model (the coefficient of variation is respectively 0.9 to 2.9 % and 0.7 to 2.1 % for PowerTap and SRM). The PowerTap must be considered as a suitable device for PO measurements during sub-maximal real road cycling and in sub-maximal laboratory tests.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validity, Sensitivity, Reproducibility, and Robustness of the PowerTap, Stages, and Garmin Vector Power Meters in Comparison With the SRM Device.

A large number of power meters have been produced on the market for nearly 20 y according to user requirements. PURPOSE To determine the validity, sensitivity, reproducibility, and robustness of the PowerTap (PWT), Stages (STG), and Garmin Vector (VCT) power meters in comparison with the SRM device. METHODS A national-level male competitive cyclist completed 3 laboratory cycling tests: a su...

متن کامل

Validity and reliability of the Wattbike cycle ergometer.

The purpose of this study was to assess the validity and reliability of the Wattbike cycle ergometer against the SRM Powermeter using a dynamic calibration rig (CALRIG) and trained and untrained human participants. Using the CALRIG power outputs of 50-1 250  W were assessed at cadences of 70 and 90  rev x min(-1). Validity and reliability data were also obtained from 3 repeated trials in both t...

متن کامل

Validity and reproducibility of the ErgomoPro power meter compared with the SRM and Powertap power meters.

PURPOSE The ErgomoPro (EP) is a power meter that measures power output (PO) during outdoor and indoor cycling via 2 optoelectronic sensors located in the bottom bracket axis. The aim of this study was to determine the validity and the reproducibility of the EP compared with the SRM crank set and Powertap hub (PT). METHODS The validity of the EP was tested in the laboratory during 8 submaximal...

متن کامل

Validity and reproducibility of the Powertap P1 power meter when compared with SRM device

Purpose: The use of power meters allows the assessment of cycling performance according to the record power profile [1]. Some power meters allow the measurement of power output (PO) in the pedals such as Look Keo Power (Look, Cedex, France) [2] and Garmin Vector (Olathe, USA) [3]. However, the results about these two systems [2, 3] should be treated with some caution given the presence of mean ...

متن کامل

Torso stabilization reduces the metabolic cost of producing cycling power.

Many researchers have used cycling exercise to evaluate muscle metabolism. Inherent in such studies is an assumption that changes in whole-body respiration are due solely to respiration at the working muscle. Some researchers, however, have speculated that the metabolic cost of torso stabilization may contribute to the metabolic cost of cycling. Therefore, our primary purpose was to determine w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of sports medicine

دوره 26 10  شماره 

صفحات  -

تاریخ انتشار 2005