Effect of Inhaler Design Variables on Paediatric Use of Dry Powder Inhalers
نویسندگان
چکیده
Age appropriateness is a major concern of pulmonary delivery devices, in particular of dry powder inhalers (DPIs), since their performance strongly depends on the inspiratory flow manoeuvre of the patient. Previous research on the use of DPIs by children focused mostly on specific DPIs or single inspiratory parameters. In this study, we investigated the requirements for a paediatric DPI more broadly using an instrumented test inhaler. Our primary aim was to assess the impact of airflow resistance on children's inspiratory flow profiles. Additionally, we investigated children's preferences for airflow resistance and mouthpiece design and how these relate to what may be most suitable for them. We tested 98 children (aged 4.7-12.6 years), of whom 91 were able to perform one or more correct inhalations through the test inhaler. We recorded flow profiles at five airflow resistances ranging from 0.025 to 0.055 kPa0.5.min.L-1 and computed various inspiratory flow parameters from these recordings. A sinuscope was used to observe any obstructions in the oral cavity during inhalation. 256 flow profiles were included for analysis. We found that both airflow resistance and the children's characteristics affect the inspiratory parameters. Our data suggest that a medium-high resistance is both suitable for and well appreciated by children aged 5-12 years. High incidences (up to 90%) of obstructions were found, which may restrict the use of DPIs by children. However, an oblong mouthpiece that was preferred the most appeared to positively affect the passageway through the oral cavity. To accommodate children from the age of 5 years onwards, a DPI should deliver a sufficiently high fine particle dose within an inhaled volume of 0.5 L and at a peak inspiratory flow rate of 25-40 L.min-1. We recommend taking these requirements into account for future paediatric inhaler development.
منابع مشابه
Asthma medication delivery: mists and myths.
Asthma is usually treated with inhaled corticosteroids (ICS) and bronchodilators generated from pressurized metered dose inhalers (pMDI), dry powder inhalers (DPI), or nebulizers. The target areas for ICS and beta 2-agonists in the treatment of asthma are explained. Drug deposition not only depends on particle size, but also on inhalation manoeuvre. Myths regarding inhalation treatments lead to...
متن کاملAsthma inhalers and subsurface enamel demineralisation: an in situ pilot study.
AIM The purpose of this pilot study was to identify the subsurface enamel demineralising potential of two possible acidogenic lactose-based powders and their corresponding generic pump inhalers. METHODS Ten healthy non-asthmatic adults participated in a 5- leg randomised crossover study including a 10% sucrose control. A twice-daily 400 microg dose of inhaler was applied in vitro to a deminer...
متن کاملMetered-dose inhalers and dry powder inhalers in aerosol therapy.
Inhaled drug delivery is an important part of the armamentarium of clinicians caring for patients with pulmonary disease. An increasing variety of metered-dose inhalers and dry powder inhalers are becoming available. This has been driven by the development of new formulations and the impending ban on chlorofluorocarbon propellants. The result is a proliferation of devices, resulting in a confus...
متن کاملEffect of terbutaline on mucociliary clearance in asthmatic and healthy subjects after inhalation from a pressurised inhaler and a dry powder inhaler.
BACKGROUND beta Agonists have been shown to increase mucociliary clearance in some studies but not all. Whether the formulation of beta agonists affects mucociliary clearance is not known but may be important as the use of dry powder inhalers increases. METHODS The effect of different methods of administration of inhaled terbutaline on mucociliary clearance and forced expiratory volume in one...
متن کامل"Pierce and inhale" design in capsule based dry powder inhalers: Effect of capsule piercing and motion on aerodynamic performance of drugs.
In this work three capsule-based dry powder inhalers, available for generics product development, were compared. Two technologically different dry powder formulations were used in order to relate the capsule piercing position and motion in the device to their aerodynamic performance. A "pierce and inhale" design, in which the capsules pierced with RS01, HandiHaler or Turbospin devices were aero...
متن کامل