Experimental test-object study of electronically collimated SPECT.
نویسندگان
چکیده
The imaging performance of a prototype electronically collimated single-photon emission computed tomography (SPECT) camera comprising a unique 4 x 4 germanium detector backed by an uncollimated scintillation camera has been evaluated. Three-dimensional images of cylindrical test-objects containing either 99mTc (140 keV) or 137Cs (662 keV) are reported. Electronically collimated counts were acquired from the objects rotated to 20 or 40 angular positions in front of the germanium detector to simulate a cylindrical scanning system. For comparison, mechanically collimated data were also acquired from the test-objects. The SPECT images show a slightly better resolution for mechanical over electronical collimation (1.3 +/- 0.25 cm mechanical, 1.5 +/- 0.25 cm electronical at 140 keV; 1.5 +/- 0.25 cm mechanical, 1.7 +/- 0.25 cm electronical at 662 keV). The equi-resolution sensitivity, however, was deduced to be approximately an order of magnitude higher with electronic collimation to image a head-sized object using 99mTc. In addition, the sensitivity gain increases with increasing energy, suggesting the unique potential of electronic collimation in high-energy SPECT.
منابع مشابه
Comparisons of Multiple Photon Coincidence Imaging Techniques
We compare analytically techniques for multiplephoton coincidence imaging in terms of spatial resolution, detector efficiency (or simply efficiency), and system sensitivity for a spherical water phantom (or simply sensitivity). One analysis consists of comparing photon-photon coincidence single-photon-emission computerized tomography (PP-SPECT) with angularly unconstrained, electronically colli...
متن کاملSystem modeling and spatial sampling techniques for simpli cation of transition matrix in 3D Electronically Collimated SPECT
transition matrix in 3D Electronically Collimated SPECT Anne C. Sauve1, Alfred O. Hero1, W. Leslie Rogers2 and Neal H. Clinthorne2 January 15, 1997 Abstract In this paper we will present numerical studies of the performance of a 3D Compton camera being developed at the University of Michigan. We present a physical model of the camera which exploits symmetries and an adapted spatial sampling pat...
متن کاملComparison of the effect of group therapy based on family systems theory and short-term object relations couple therapy on the women’s marital intimacy
Background & Aims: The aim of present study was to compare the effect of group therapy based on family systems theory and short-term object relations couple therapy on the women’s marital intimacy. Material & Method: The research design in this study was pre-test, post-test experimental method with control group. The statistical population was included female clients of 25-55 years old with mar...
متن کاملComparison of transient ischemic dilation ratios in SPECT and SPECT-CT myocardial perfusion imaging in the low pre-test probability group
Introduction: The main purpose of this study was to compare transient ischemic dilation (TID) ratios in SPECT-low dose CT and SPECT Myocardial Perfusion Imaging (MPI) by application of different quantitative programs and quantify the possible shift in the upper normal limits of TID ratio in the SPECT-CT MPI. Methods: 149 Patients with low pre-test probability for coronary artery disease (CAD),...
متن کاملQuantitative SPECT and planar 32P bremsstrahlung imaging for dosimetry purpose –An experimental phantom study
Background: In this study, Quantitative 32P bremsstrahlung planar and SPECT imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate Dosimetry in clinical practice. Materials and Methods: CT, planar and SPECT bremsstrahlung images of Jaszczak phantom containing a known activity of 32P were acquired. In addition, Phanto...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 31 2 شماره
صفحات -
تاریخ انتشار 1990