3D Local Measurements of Bone Strain and Displacement: Comparison of Three Digital Volume Correlation Approaches

نویسنده

  • Marco Palanca
چکیده

LONG) Background. Different Digital Volume Correlation (DVC) approaches are currently available or under development for bone tissue micromechanics. The aim of this study was to compare accuracy and precision errors of three DVC approaches for a particular 3D zero-strain condition. Method of approach. Trabecular and cortical bone specimens were repeatedly scanned with a micro-CT. The errors affecting computed displacements and strains were extracted for a known virtual translation, as well as for repeated scans. Three DVC strategies were tested: two local approaches, based on FastFourier-transform (DaVis-FFT) or Direct-Correlation (DaVis-DC), and a global approach based on elastic registration and a finite element solver (ShIRT-FE). Different computation sub-volume sizes were tested. Results. Much larger errors were found for the repeated scans, than for the virtual translation test. For each algorithm, errors decreased asymptotically for larger sub-volume sizes in the range explored. Considering this particular set of images, ShIRT-FE showed an overall better accuracy and precision (a few hundreds microstrain for a sub-volume of 50 voxels). When the largest sub-volume (50-52 voxels) was applied to cortical bone, the accuracy error obtained for repeated scans with ShIRT-FE was approximately half of that for the best local approach (DaVis-DC). The difference was lower (250 microstrain) in the case of trabecular bone. In terms of precision, the errors shown by DaVis-DC were closer to the ones computed by ShIRT-FE (differences of 131 microstrain and 157 microstrain for cortical and trabecular bone, respectively). The multi-pass computation available for DaVis software improved the accuracy and precision only for the DaVis-FFT in the virtual translation, particularly for trabecular bone. The better accuracy and precision of ShIRT-FE, followed by DaVis-DC, were obtained with a higher computational cost when compared to DaVis-FFT. Conclusions. The results underline the importance of performing a quantitative comparison of DVC methods on the same set of samples by using also repeated scans, other than virtual translation tests only. ShIRT-FE provides the most accurate and precise results for this set of images. However, both DaVis approaches show reasonable results for large nodal spacing, particularly for trabecular bone. Finally, this study highlights the importance of using sufficiently large sub-volumes, in order to achieve better accuracy and precision.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Efficacy of Digital Caliper and a Newly Designed Digital Bone Gauge for Measurement of Edentulous Alveolar Ridge Width

Objectives: An efficient, safe, affordable and easily accessible measuring instrument for quantitative assessment of bone prior to dental implant placement enables more accurate treatment planning. Costly imaging modalities are neither widely available, nor affordable for some patients. This study sought to assess the efficacy of a newly designed digital bone gauge for measurement of bone width...

متن کامل

Predicting three-dimensional displacement around the tunnel and its impact on the value of Q-system

Having knowledge of stability of an underground space depends on stresses and strains around it. Creating underground tunnels leads to significant changes in the rock mass stress. Therefore, to achieve the necessary stability, stresses and deformations around the tunnel must be examined carefully. Usually, stress-strain behavior analysis is conducted in two-dimensional mode. This paper was cond...

متن کامل

A three-dimensional digital image correlation technique for strain measurements in microstructures.

A three-dimensional digital image correlation technique is presented for strain measurements in open-cell structures such as trabecular bone. The technique uses high-resolution computed tomography images for displacement measurements in the solid structure. In order to determine the local strain-state within single trabeculae, a tetrahedronization method is used to fill the solid structure with...

متن کامل

Computation of full-field displacements in a scaffold implant using digital volume correlation and finite element analysis.

Measurements of three-dimensional displacements in a scaffold implant under uniaxial compression have been obtained by two digital volume correlation (DVC) methods, and compared with those obtained from micro-finite element models. The DVC methods were based on two approaches, a local approach which registers independent small volumes and yields discontinuous displacement fields; and a global a...

متن کامل

Study of mechanical behavior of cancellous bone by Digital Volume Correlation and X-ray Micro-Computed Tomography

This paper presents a study of mechanical behavior of human cancellous bone during a compression loading. Mechanical test is performed inside an X-ray tomography device allowing us to generate a volume image for each loaded step. Digital Volume Correlation (DVC) process has been developed and applied on these volume images. Full 3D displacement field is determined by DVC leading to the calculat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015