Effects of reduced dialysis fluid flow in hemodialysis.
نویسندگان
چکیده
BACKGROUND Hemodialysis is a treatment in which uremic toxins and excess water content are removed from the blood with a dialyzer and dialysis fluid. The efficiency of hemodialysis is strongly influenced by the following 3 parameters: the blood flow rate (QB), the dialysis fluid flow rate (QD), and the overall mass transfer area coefficient (K0A), an index of a dialyzer's performance. The flow ratio (QB : QD) to obtain a well-balanced dialysis efficiency is generally said to be 1 : 2. In Japan, the QB is controlled independently (from 200 to 250 mL/min) depending on individual conditions. However, the QD is usually set at around 500 mL/min regardless of the QB. MATERIALS AND METHODS To investigate the effect on dialysis efficiency of decreasing the QD from 500 to 400 mL/min, 12 patients were divided into two groups: one in which the QB was 150 mL/min, with 1.3-m(2) membranes; and another in which the QB was 200 mL/min, with 1.6-m(2) membranes. We defined the conditions with the QD of 500 mL/min as condition A, and that with the QD of 400 mL/min as condition B. Each operating condition was assigned for 2 weeks as crossover trials. To evaluate solute removal, we calculated clearance, reduction rate, removal amount, clear space, the clear space rate, and albumin leakage. Furthermore, when dialysis efficiency decreased in condition B, we performed a supplementary test: we calculated the QB with the K0A equation to achieve a dialysis efficiency equivalent to that in condition A, defined as condition B', as the operating condition with the calculated QB and a QD of 400 mL/min, and re-evaluated. RESULTS In condition B, a QB of 150 mL/min had no effect on the dialysis efficiency;whereas with a QB of 200 mL/min, slight yet significant differences were observed in the clearance of small molecular weight solutes. Condition B' (QB=210 mL/min) showed an equivalent or greater dialysis efficiency and demonstrated an association with theoretical values. CONCLUSIONS In hemodialysis, the flow ratio (QB : QD) should be maintained at 1 : 2 to obtain a well-balanced dialysis efficiency. The present study has shown that the QD can be decreased while maintaining this flow ratio. A well-balanced QD setting can be financially and environmentally conscious. In addition, use of the K0A equation is a highly effective method to calculate a QB that allows an expected dialysis efficiency to be achieved in case the QD needs to be decreased uniformly, as when dialysis fluid is in short supply during times of disaster.
منابع مشابه
Comparative Analysis of Serum Levels of Aluminum and Lead in Dialysis Patients, Pre and post Dialysis
Background: Accumulation or deficiency of trace elements can occur in hemodialysis patients and it increases risk of cardiovascular or other organs disorders. Special ions levels such as sodium and bicarbonate in dialysis fluid are accurately regulated but the remaining elements are not regularly measured. Aluminum and lead belong to the biologic performance free heavy metals .They also has a t...
متن کاملDialysis adequacy of chronic hemodialysis patients in Zanjan-Iran, 2016
Background: Dialysis adequacy is one of the most important factors in determining the survival rate and mortality of dialysis patients. Objectives: The aim of this study was to determine the dialysis adequacy of patients undergoing chronic hemodialysis at dialysis centers located in the province of Zanjan, located in northwest Iran. Methods: This descriptive cross-sectional study was performe...
متن کاملDetermination of the serum level of aluminum & zinc in hemodialysis patients in Kerman,Iran
Dialysis is one of the effective methods which has been used since 1955 for the treatment of patients suffering from renal failure( more often of its chronic type). The dialysis results in the elimination of waste materials like urea and creatinine from the body, on the other hand, it can affect the serum contamination of the dialysis fluid. Aluminium is one of trace elements which its serum le...
متن کاملSpirometric Parameters: Hemodialysis Compared to Peritoneal Dialysis
Introduction: Renal failure affects the mechanical and the ventilatory function of the lungs. A few studies have evaluated the ventilatory and pulmonary function in dialysis patients. The present study aimed to compare Pulmonary Function Test (PFT) results in patients undergoing Hemodialysis (HD) and Peritoneal Dialysis (PD). Materials and Methods: We conducted a cross-sectional study on 50 pa...
متن کاملEffect of ice chips on intensity of thirst and fluid intake in patients undergoing hemodialysis
Background: Thirst is the most common complaint of patients undergoing hemodialysis with stimulating the patient to drink more fluids result in intradialytic weight gain. Thirst leads to some complication including heart problem which is one of the most common causes of death in these patients. Aim: To determine the effect of ice chips on thirst and fluid intake of patients undergoing hemodialy...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of Nippon Medical School = Nippon Ika Daigaku zasshi
دوره 80 2 شماره
صفحات -
تاریخ انتشار 2013